Pierce Manufacturing: Overloaded Electrical System May Cause Fire
Estimated risk
NHTSA doesn't classify recalls by risk and gave no do-not-drive or park-outside warning for this one, so Recall Relay estimated the risk as high from the recall's description (it mentions a risk such as fire, serious injury or death). This is our estimate, not an official classification.
- Hazard
- Overloaded electrical circuits can overheat, increasing the risk of fire.
- What to do
- Pierce will work with the equipment manufacturer Weldon to update the firmware, free of charge. Owner notification letters were mailed February 26, 2024. Owners may contact Pierce customer service at 1-888-974-3723. Pierce's number for this recall is Pierce 74B332.
- Products
-
- Overloaded Electrical System May Cause Fire
- Company
- Pierce Manufacturing
- Where it was sold
-
Nationwide
- Units affected
- 248
- About this recall
- Pierce Manufacturing (Pierce) is recalling certain 2020-2023 Freightliner and International Chassis vehicles equipped with Weldon 8X16 Input-Output nodes. In the event of a short circuit or wiring failure, the firmware in the node may fail to shut off the output pin, resulting in overloaded electrical circuits.