Skip to content

All recalls NHTSA

NHTSAVehiclesRecalled Status: Ongoing

Pierce Manufacturing: Overloaded Electrical System May Cause Fire

Highest. risk

Estimated risk

NHTSA doesn't classify recalls by risk and gave no do-not-drive or park-outside warning for this one, so Recall Relay estimated the risk as high from the recall's description (it mentions a risk such as fire, serious injury or death). This is our estimate, not an official classification.

Hazard
Overloaded electrical circuits can overheat, increasing the risk of fire.
What to do
Pierce will work with the equipment manufacturer Weldon to update the firmware, free of charge. Owner notification letters were mailed February 26, 2024. Owners may contact Pierce customer service at 1-888-974-3723. Pierce's number for this recall is Pierce 74B332.
Products
  • Overloaded Electrical System May Cause Fire
Where it was sold

Nationwide

Units affected
248
About this recall
Pierce Manufacturing (Pierce) is recalling certain 2020-2023 Freightliner and International Chassis vehicles equipped with Weldon 8X16 Input-Output nodes. In the event of a short circuit or wiring failure, the firmware in the node may fail to shut off the output pin, resulting in overloaded electrical circuits.