Ion Beam Applications S.A. recalls
Ion Beam Applications S.A. is named on 6 recalls in Recall Relay's records since November 2023, from FDA; the most recent was February 3, 2026.
All 6, newest first.
-
Class IIofficial
Ion Beam Applications S.A. recalls IBA Proton Therapy System - PROTEUS 235It was identified that eh Universal Beam Triggering Interface (UBTI) is disabled in the Therapy Safety System (TSS) configuration. In this condition, the TSS does not interrupt the beam delivery if the Healthy Signal from an external gating device is lost. This may lead to a risk of mistreatment when external gating devices are used.
-
Class IIofficial
Ion Beam Applications S.A. recalls IBA Proton Therapy System - PROTEUS 235- Designed to produce and deliver a proton beam for the treatment of paTemporary deactivation of collision detection for Forte Robotic Patient Positioning System occasionally experiences issues
-
Class IIofficial
Ion Beam Applications S.A. recalls IBA Proton Therapy System - PROTEUS 235 ProteusPLUS and ProteusONE Software versions: PTS-8 versionsSafety Parameters Verification Mechanisms can be deactivated in clinical runtime
-
Class IIofficial
Ion Beam Applications S.A. recalls IBA Proton Therapy System - PROTEUS 235 - Designed to produce and deliver a proton beam for the treatment of pIrradiation is not interrupted when some C230 Accelerator Control Unit critical parameters are outside of the defined tolerances
-
Class IIofficial
Ion Beam Applications S.A. recalls IBA Proton Therapy System - PROTEUS 235There is a risk of mistreatment as irradiation is not prevented when some safety parameters are out of tolerance.
-
Class IIofficial
Ion Beam Applications S.A. recalls IBA Proton Therapy System - PROTEUS 235. PTS-11 versionsThe patient positioning system can perform motions in unexpected directions, creating the potential for crushing of the patient between the patient positioning devices.
This page groups recalls by the company name the agency printed, so it can include different companies with similar names, and a recall may name a store or distributor rather than the maker. It counts the recalls in Recall Relay's records, not a company's whole history; an FDA recall that lists several products counts once. Open a recall to see its details and the agency's official notice, which is always the final word. Recall Relay isn't affiliated with any agency or with the companies named here.