All recalls
Every recall from CPSC, FDA, USDA and NHTSA, newest first. Each one links to the agency's official notice. Looking for one product? Check a product.
9,320 recalls ยท page 29 of 187
-
Class Iofficial
Medline Industries, LP recalls Medline kits containing Huons Co. Bupivacaine HCL in Dextrose InjectionMedline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and reported efficacy complaints.
-
Class Iofficial
Medline Industries, LP recalls Medline kits containing Huons Co. Bupivacaine HCL in Dextrose InjectionMedline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and reported efficacy complaints.
-
Class Iofficial
Medline Industries, LP recalls Medline kits containing Huons Co. Bupivacaine HCL in Dextrose InjectionMedline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and reported efficacy complaints.
-
Class Iofficial
Medline Industries, LP recalls Medline kits containing Huons Co. Bupivacaine HCL in Dextrose InjectionMedline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and reported efficacy complaints.
-
Class Iofficial
Medline Industries, LP recalls Medline kits containing Huons Co. Bupivacaine HCL in Dextrose InjectionMedline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and reported efficacy complaints.
-
Class Iofficial
Medline Industries, LP recalls Medline kits containing Huons Co. Bupivacaine HCL in Dextrose InjectionMedline kits were distributed containing Huons Bupivacaine Hydrochloride in Dextrose Injection, USP, which was subsequently recalled due to quality issues, including microbiology testing data integrity concerns and reported efficacy complaints.
-
Class IIofficial
Medline Industries, LP recalls Medline medical convenience kit labeled as EYE TRAY-LFSpecific Medline Kits contain Cardinal Health Monoject 1mL Luer Lock Syringes, Tuberculin Print, Sterile. Cardinal Health has recalled these syringes because the outer carton and blister pack are labeled as a 1 mL Luer Lock Tuberculin Syringe (Product Code 1180100777), but the syringes inside are U-100 insulin syringes.
-
Class IIofficial
Stryker Corporation recalls Thermedx FluidSmart Urology Tube Set REF LL0006 UDI-DI code: 00860936000365 The FluidSmart Tube Sets are intenDue to nonconforming products being inadvertently distributed.
-
Class IIofficial
Hologic, Inc recalls SELENIA DIMENSIONS MAMMOGRAPHY SYSTEMS. Model Numbers: SDA-SYS-3000-2D-HTCComplaints have been received of systems developing loose, missing, or broken internal bolts over time.
-
Class IIofficial
Hologic, Inc recalls 3DIMENSIONS MAMMOGRAPHY SYSTEM; Model Numbers: 3DM-SYS-INTL2DComplaints have been received of systems developing loose, missing, or broken internal bolts over time.
-
Class IIofficial
Medtronic Neuromodulation recalls Medtronic SynchroMed Flex Infusion Mode - A810 Clinician Programmer Software ApplicationSoftware issue: When programming the SynchroMed Pump with the A810 CP App in Flex Infusion Mode, the infusion steps should automatically be arranged in consecutive order, from earliest to latest. However, in rare cases, the steps may be displayed out of order. If this occurs, the programmed Flex Infusion schedule will not be delivered at the intended time, if at all.
-
Class IIofficial
Becton, Dickinson and Company recalls Swan-Ganz CatheterCatheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss.
-
Class IIofficial
Becton, Dickinson and Company recalls Swan-Ganz Jr CatheterCatheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss.
-
Class IIofficial
Becton, Dickinson and Company recalls Swan-Ganz Pacing CatheterCatheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss.
-
Class IIofficial
Becton Dickinson & Co. recalls BD GasPak EZ CO2 Pouch System. Catalog Number: 260684. for microbiologic useBD identified an issue affecting certain lots of BD GasPak EZ CO2 and BD GasPak EZ Campy Gas Generating Pouch Systems, where gas generating sachets may produce carbon dioxide levels below specification.
-
Class IIofficial
Becton Dickinson & Co. recalls BD GasPak EZ Campy Pouch System. Catalog Number: 260685. for microbiologic useBD identified an issue affecting certain lots of BD GasPak EZ CO2 and BD GasPak EZ Campy Gas Generating Pouch Systems, where gas generating sachets may produce carbon dioxide levels below specification.
-
Class IIofficial
Quidel Corporation recalls QuickVue Dipstick Strep A TestProduct has the potential for false positive results
-
Class IIofficial
Microvention Inc. recalls LVIS Intraluminal Support DeviceStent-assisted coiling device may due to commingling during manufacturing have dimensional nonconformance and/or incorrect device configuration. If device is oversized may lead to increased vessel wall stress, neointimal hyperplasia, vessel injury/rupture; if undersized may lead to incomplete expansion/malposition, acute stent thrombosis, distal embolization, ischemic neurological events
-
Class IIofficial
Stryker Neurovascular recalls INZONE DETACHMENT SYSTEMEmbolization coil detachment system devices may experience premature battery drain causing devices to: 1) Not power on; 2) Power on with faint audible and visual indicators; 3) Be unable to detach a coil as intended, which may necessitate medical intervention if the procedure must be completed with an alternative technique.
-
Class IIofficial
Wilcox Industries Corp. recalls The intended use is to be paired with a weapon for aiming purposes.Wilcox is notifying all customers who have purchased a product from the BOSS Xe family that a software enhancement to increase safety has been released and all units should be returned to implement this change.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Depuy (ireland) recalls Depuy SynthesThe external sterile packaging was found adhered to the internal sterile packaging, potentially compromising sterility.
-
Class IIofficial
Grace Medical, Inc. recalls TITANIUM/FLUOROPLASTIC PISTON 0.6MM DIA X 3.75MM L Model/Catalog Number: 409-375 Product Description: Stapes PDue to incorrect functional length on device labeling.
-
Class IIofficial
Elekta, Inc. recalls Brand Name: Fletcher CT/MR Shielded Applicator Set Product Name: Intracavitary Remote Afterloading ApplicatorDue to safety concerns regarding the detachment of the tip of the intrauterine tube (IU tube) that may remain within a patient.
-
Class IIofficial
Elekta, Inc. recalls Brand Name: Brachytherapy Applicator Product Name: Advanced Gynecological Applicator Product Description: TheDue to safety concerns regarding the detachment of the tip of the intrauterine tube (IU tube) that may remain within a patient.
-
Class IIofficial
Elekta, Inc. recalls Brand Name: Geneva Product Name: Brachytherapy Applicator Product Description: The device is intended for intrDue to safety concerns regarding the detachment of the tip of the intrauterine tube (IU tube) that may remain within a patient.
-
Class Iofficial
Cook Incorporated recalls Centimeter Sizing Catheter RPN N5.0-35-100-P-10S-PIG-CSC-20 GPN G11916 Catheters for use in angiographic proceMarker bands may be at an increased risk of cracking/breakage. Potential adverse events that may result include increased procedural time, harms associated with device fragmentation/separation, and vessel injury. In a worst-case scenario, device fragmentation and separation may cause life-threatening harm or death.
-
Class Iofficial
Cook Incorporated recalls Aurous Centimeter Sizing Catheter RPN N5.0-35-100-P-10S-PIG-CSC-20-01 GPN G47308 Sizing catheters are single-uMarker bands may be at an increased risk of cracking/breakage. Potential adverse events that may result include increased procedural time, harms associated with device fragmentation/separation, and vessel injury. In a worst-case scenario, device fragmentation and separation may cause life-threatening harm or death.
-
Class Iofficial
Cook Incorporated recalls Beacon Tip Centimeter Sizing Catheter RPN/GPN NR5.0-35-70-P-10S-0-CSC-20 G31213 NR5.0-35-100-P-10S-0-CSC-20 G3Marker bands may be at an increased risk of cracking/breakage. Potential adverse events that may result include increased procedural time, harms associated with device fragmentation/separation, and vessel injury. In a worst-case scenario, device fragmentation and separation may cause life-threatening harm or death.
-
Class IIofficial
Merit Medical Systems, Inc. recalls Philips Bridge Prep Kit REF: K12-09098B Sterile EOcatheter may experience resistance when being advanced over the guidewire
-
Class IIofficial
Merit Medical Systems, Inc. recalls Philips Bridge Prep Kit REF: K12-09098C Sterile EOcatheter may experience resistance when being advanced over the guidewire
-
Class IIofficial
Merit Medical Systems, Inc. recalls Philips Bridge Prep Kit REF: K12-09098C Sterile EOcatheter may experience resistance when being advanced over the guidewire
-
Class IIofficial
Siemens Healthcare Diagnostics Inc recalls epoc BGEM BUN Test Card (25 pk) for the epoc Blood Analysis System; Siemens Material Number (SMN): 10736515;Use of the affected product can result in discrepant low pH and measured Total Carbon Dioxide (mTCO2) results and corresponding calculated values in arterial, venous, and capillary patient samples. An erroneously low pH or mTCO2 reading can lead to inappropriate treatment of nonexistent acidosis (respiratory of metabolic) or missed diagnosis of alkalosis (a true high pH: respiratory or metabolic alkalosis), potentially causing harm through unnecessary interventions with the former or failure to deliver appropriate treatment with the latter.
-
Class IIofficial
Intuitive Surgical, Inc. recalls Brand Name: Da Vinci X and Da Vinci Xi Product Name: da Vinci XDue to manipulator containing screws with in the arm sub-assembly that my be susceptible to breaking.
-
Class Iofficial
Windstone Medical Packaging, Inc. recalls Custom Convenience Kit containing recalled Medline Namic Angiographic Control Syringes with Rotating Adapter (Affected kits contain Medline Namic RA Syringes, which are recalled by their manufacturer due to risk of syringe rotating adapter unwinding during use, which may result in a loose connection or full disconnection between syringe and manifold. If unwinding occurs, there is a potential for biohazard exposure, blood loss, infection. or air embolism.
-
Class IIofficial
DFI Co., Ltd. recalls One Step 10A in vitro diagnostic testThe devices were distributed without required FDA premarket clearance or approval.
-
Class IIofficial
DFI Co., Ltd. recalls One Step UTI in vitro diagnostic test REF: 3374The devices were distributed without required FDA premarket clearance or approval.
-
Class IIofficial
DFI Co., Ltd. recalls One Step pH in vitro diagnostic test REF: 31I4PThe devices were distributed without required FDA premarket clearance or approval.
-
Class IIofficial
DFI Co., Ltd. recalls QUCARE Total Cholesterol in vitro diagnostic test REF: 6407The devices were distributed without required FDA premarket clearance or approval.
-
Class IIofficial
DFI Co., Ltd. recalls Uric Acid in vitro diagnostic test REF: 31H0PThe devices were distributed without required FDA premarket clearance or approval.
-
Class IIofficial
DFI Co., Ltd. recalls One Step K in vitro diagnostic test REF: 81A4The devices were distributed without required FDA premarket clearance or approval.
-
Class IIofficial
DFI Co., Ltd. recalls One Step P in vitro diagnostic test REF: 8194The devices were distributed without required FDA premarket clearance or approval.
-
Class IIofficial
Abbott Point Of Care Inc. recalls i-STAT EG7+ cartridge; List Number: 03P76-25;Approximately 7.6% of cartridges from specific i-STAT EG7+ (list number 03P76-25), i-STAT EG6+ (list number 03P77-25) and i-STAT G3+ (list number 03P78-26) cartridge lots in the U.S. marketplace may report higher than expected PCO2 and lower than expected pH results due to a manufacturing issue. A falsely high pCO2 together with a falsely low pH makes the blood gas appear as if the patient is in severe respiratory acidosis. If the clinician believes the values are real, it may trigger unnecessary or even harmful interventions such as unnecessary ventilator changes, unnecessary medications, potential harm from overcorrection, or delays in identifying true problems.