All recalls
Every recall from CPSC, FDA, USDA and NHTSA, newest first. Each one links to the agency's official notice. Looking for one product? Check a product.
9,320 recalls · page 68 of 187
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 OR Table; Model Numbers: (1) 722015The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/10; Model Numbers: 722029; Associated 510(k)s: K102005The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/15; Model Numbers: 722058; Associated 510(k)s: K102005The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/15 OR Table; Model Numbers: 722059; Associated 510(k)s: K102005The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/20; Model Numbers: 722038; Associated 510(k)s: K102005The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/20 OR Table; Model Numbers: 722039; Associated 510(k)s: K102005The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper CV20; Model Numbers: 722031; Associated 510(k)s: K102005The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Cardio Vascular-Allura Centron; Model Numbers: 722400; Associated 510(k)s: K102005The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.
-
Class IIofficial
Beckman Coulter Inc. recalls SYNCHRON Systems Phosphorus (PHOSm) Reagent REF: 467868 For In Vitro Diagnostic UseSpecific SYNCHRON Systems Modular Chemistry Phosphorus (PHOSm REF 467868) reagent lots may fail calibration before the lot expiration date which causes a delay in obtaining patient results.
-
Class IIofficial
Inpeco S.A. recalls FlexLab (FLX) System. Potassium Test System. in vitro diagnosticThe FlexLab System Sample Integrity Module (SIM) includes function that determines the hemolysis, icterus, and lipemia (HIL) in blood samples. This function has not been evaluated for safety and effectiveness by the FDA, so its use may cause an increase in erroneous results or a delay in patient results.
-
Class IIofficial
Inpeco S.A. recalls FlexLab X (FXX) System. Potassium Test System. in vitro diagnosticThe FlexLab X System Sample Integrity Module (SIM) includes function that determines the hemolysis, icterus, and lipemia (HIL) in blood samples. This function has not been evaluated for safety and effectiveness by the FDA, so its use may cause an increase in erroneous results or a delay in patient results.
-
Class IIofficial
Fresenius Kabi USA, LLC recalls Ivenix Infusion System (IIS)Potential issue that can cause the device to register "phantom" touches in the lower-left corner of the touchscreen during operation.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD10 Product Codes: (1)722010Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD10/10 Product Codes: (1)722011Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD10 OR Table Product Codes: (1)722022Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 Product Codes: (1)722012Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 Biplane Product Codes: (1)722013Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 OR Table Product Codes: (1)722023Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 Biplane OR Table Product Codes: (1)722020Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/20; Product Code: 722038; Associated 510(k) numbers: K102005Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/20 OR Table; Product Code: 722039; Associated 510(k) numbers: K102005Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/10; Product Code: 722029; Associated 510(k) numbers: K102005Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/15; Product Code: 722058; Associated 510(k) numbers: K102005Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/15 OR Table; Product Code: 722059; Associated 510(k) numbers: K102005Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura CV20; Product Code: 722031; Associated 510(k) numbers: K102005Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational for floor mounted systems) and table longitudinal movements remain available. Imaging (X-ray) functionality remains available.
-
Class IIofficial
LeMaitre Vascular, Inc. recalls Artegraft Collagen Vascular Grafts Model Numbers: (1) AG 616The bovine carotid arteries used to produce the impacted grafts from affected lots were sourced using raw material from a supplier that had not been reviewed and approved by the appropriate regulatory authority.
-
Class IIofficial
Canon Medical System, USA, INC. recalls This device is a digital radiography/fluoroscopy system used in a diagnostic and interventional angiography coIt has been found that when SPOT Fluoro is first turned on, the default ROI is selected and the collimator blades move to the boundary of the ROI, and the static image is overlayed around the ROI, covering the collimated area. If the customer changes the ROI, the collimator blades and static images are adjusted accordingly. However, when the acquisition program is changed, the collimator returns to the default ROI position which may be larger than the specified one, leaving the X-ray area partially covered by the static image. This is a software problem with the SPOT Fluoro program and will not occur if the function is not used.
-
Class IIofficial
Berkeley Advanced Biomaterials, LLC recalls Tribio Implant 7.5mm x 40mm REF M80 SB008 UDI code: (01) 00816125023653(10) EBL10B13C(17) 270630 Tribio" ImplaDue to incorrect product label (Incorrect product name identified on outer packaging).
-
Class IIofficial
Getinge Disinfection Ab recalls Getinge 88-Series Washer- Disinfector. Model Number: 88-5.Potential for device to overheat during operation if the circulation pressure calibration was not performed or had been performed incorrectly, and the low-pressure alarm is not triggered.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 0.9mm OTW Turbo Elite Laser Atherectomy Catheter. Model Number: R-410-152. The NES ReprocessedPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 1.4mm OTW Turbo Elite Laser Atherectomy Catheter. Model Number: R-414-151. The NES ReprocessedPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 1.7mm OTW Turbo Elite Laser Atherectomy Catheter. Model Number: R-417-152. The NES ReprocessedPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 2.0mm OTW Turbo Elite Laser Atherectomy Catheter. Model Number: R-420-006. The NES ReprocessedPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 0.9mm RX Turbo Elite Laser Atherectomy Catheter. Model/Catalog Number: R-410-154. The NES ReprPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 1.4mm RX Turbo Elite Laser Atherectomy Catheter. Model Number: R-414-159. The NES ReprocessedPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 1.7mm RX Turbo Elite Laser Atherectomy Catheter. Model Number: R-417-156. The NES ReprocessedPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
Northeast Scientific Inc. recalls NES Reprocessed 2.0mm RX Turbo Elite Laser Atherectomy Catheter. Model Number: R-420-159. The NES ReprocessedPotential for breaches in the sterile barrier packaging, compromising sterility assurance.
-
Class IIofficial
ImaCor Inc. recalls ClariTEE Miniaturized TEE probe. Model Number: CLT-010. Ultrasound miniaturized TEE probe for use with MobileProduction assembly error resulting in the potential for reversed articulation, where moving the lever forward caused the probe tip to anteflex rather than retroflex, and vice versa.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls Optiflux¿ High Flux E-beam Dialyzer Model Numbers: (1) 0500316E OPTIFLUX F160NRe 12/CS 1.5SA EBEAMTo provide further information to the user to ensure proper use of the medical device. the caps had been changed from a threaded version to a press-on version whereby the user must press the caps firmly onto the dialyzer to securely affix the cap.
-
Class IIofficial
ConvaTec, Inc recalls DuoDERM" Extra Thin dressings are highly flexibleWound dressing may have foreign matter on the product.
-
Class IIofficial
Baxter Healthcare Corporation recalls CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK System Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM EXTENSION SETIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM EXTENSION SETIV sets may leak.