Baxter Healthcare Corporation recalls CLEARLINK SYSTEM EXTENSION SETIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK System Non_DEHP Extenstion SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM CONTINU-FLO Solution SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK System Paclitaxel SetIV sets may leak.
-
Class IIofficial
Baxter Healthcare Corporation recalls CLEARLINK SYSTEM NON-DEHP CONTINU-FLO SOLN SETIV sets may leak.
-
Class IIofficial
BigTree Sales Inc. recalls The product is a handheld ultraviolet-C germicidal wand and contains a narrow-diameterThe subject product emits unsafe level of UVC radiation (i.e., the product reaches the exposure limit for Risk Group 3 (high risk) in about 2.2 minutes). The product has a radiation safety defect, in that these radiation emissions are unnecessary to the accomplishment of the product s primary purpose of disinfecting objects and surfaces, and create a risk of skin and/or eye injuries to user and nearby persons.
-
Class Iofficial
Dexcom, Inc. recalls Brand Name: Dexcom G6 Continuous Glucose Monitoring System Product Name: Dexcom G6 and G6 Pro Android US CGM AA software defect in version v1.15.0 of the G6 Android app can cause the app to terminate unexpectedly, which may result in the user not receiving estimated glucose values, alarms, alerts or notifications. This could result in the missed detection of a hyperglycemic or hypoglycemic event, protentional resulting in severe hyperglycemia, diabetic ketoacidosis (DKA), or hyperosmolar hyperglycemic state (HHS).
-
Class IIofficial
Vantive US Healthcare LLC recalls Sharesource Connectivity Platform for Use with Homechoice Claria Product Code 5CGM01 software versions 7.13.3Vantive has identified a software defect within the Sharesource Claria software, which may cause a patient s updated prescription program settings to not be properly saved on the actual cycler that the patient is using to perform their therapy. As a result, the clinician may think that the patient is receiving the correct prescribed therapy because of what is erroneously displayed on the clinician's remote Sharesource application, when in fact the cycler that is with the patient is actually delivering an outdated and incorrect therapy.
-
Class IIofficial
Boston Scientific Corporation recalls Extractor Pro RX Retrieval Balloon Catheter; UPN (REF): (1) M00547030 (9-12mm Below)The product in incorrectly labeled. The label indicates that the skive hole should be above the balloon, while it is actually positioned below, and vice versa.
-
Class IIofficial
Howmedica Osteonics Corp. recalls 1. EXETER V40 STEM 44MM NO 2a potential product mix where the package labeled as Catalog Number 0580-1-442, lot A00976, may contain Catalog Number 0580-1-352, lot G8754849, and vice versa. Patient labels may also be impacted.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls Biograph mMR. Model Number: 10433372.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls BIOGRAPH One (DE). Model Number: 11689172.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Cima.X (DE). Model Number: 11647158.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Connectom.X. Model Number: 11371480.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Lumina (DE). Model Number: 11344916.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Prisma. Model Number: 10849582.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Skyra (DE). Model Number: 10432915. 510(k) Numbers: K101347There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Skyra fit. Model Number: 10849580.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Skyra Fit BioMatrix. Model Number: 11516217.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Spectra as the following: 1. MAGNETOM Spectra. Model Number: 10837643. 2. MAGNETOM Spectra (CN). ModeThere is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Verio. Model Number: 10276755.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Verio Dot. Model Number: 10684333.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Verio Dot Upgrade. Model Number: 10684334.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Vida (DE). Model Number: 11060815. 510(k): K170396There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class Iofficial
Siemens Medical Solutions USA, Inc recalls MAGNETOM Vida Fit. Model Number: 11410481.There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
-
Class IIofficial
Vision RT Ltd recalls The AlignRT InBore system contains six Class 1 lasers which enables the system s cameras to track the patientVision RT is informing customers of an omission identified in the Instructions for Use for AlignRT InBore systems. Information identifying the lasers and their characteristics was omitted from the Instructions for Use for the subject system as required by 21 CFR 1040,10(h), via conformance with recognized consensus standard IEC 60825-1 Ed. 3 (FDA Laser Notice 56).
-
Class IIofficial
W L Gore & Associates, Inc. recalls GORE ACUSEAL Vascular GraftReports of vascular graft delamination, which may lead to reduced access flow; cannulation difficulties; bleeding or bruising; and harms related to reintervention procedures, so Instructions for Use will be updated to modify existing warning to 1) further clarify techniques that may contribute to the risk of delamination, 2) Addition of delamination to device-related adverse event section.
-
Class IIofficial
OSSTEM Implant Co., Ltd. recalls Osstem Dental X-Ray System T1. Product Model Numbers T1-C and T1-CS.Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regulations). Specifically, the following statement may have been omitted: Certification Statement: This electronic product complies with all applicable performance standards prescribed under 21 CFR Subchapter J, as enforced by the U.S. Food and Drug Administration at the date of manufacturing.
-
Class IIofficial
OSSTEM Implant Co., Ltd. recalls Osstem Dental X-Ray System T2. Product Model Numbers T2-C and T2-CS.Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regulations). Specifically, the following statement may have been omitted: Certification Statement: This electronic product complies with all applicable performance standards prescribed under 21 CFR Subchapter J, as enforced by the U.S. Food and Drug Administration at the date of manufacturing.
-
Class IIofficial
OSSTEM Implant Co., Ltd. recalls Osstem Dental X-Ray System T2Plus. Product Model Numbers T2-C-P and T2-CS-P.Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regulations). Specifically, the following statement may have been omitted: Certification Statement: This electronic product complies with all applicable performance standards prescribed under 21 CFR Subchapter J, as enforced by the U.S. Food and Drug Administration at the date of manufacturing.
-
Class IIofficial
LeMaitre Vascular, Inc. recalls Artegraft Collagen Vascular Graft. Model/Catalog/Part Numbers: AG630MDevices were distributed with incorrect label without CE and UKCA mark, missing patient leaflet and patient implant card.
-
Class IIofficial
GE Medical Systems, LLC recalls MAC VU360 Acquisition Trunk Cable and Module HolderIf a user incorrectly places the Acquisition Module into the Acquisition Module Holder, it can result in excessive bending and wear of the Acquisition Trunk Cable. This is visible as a damaged sheath or exposed wires. If a damaged Acquisition Trunk Cable is not recognized and removed from service, the cable can overheat with continued use.
-
Class IIofficial
Sonesta Medical AB recalls Brand Name: Sonesta Product Name: 6210 Model/Catalog Number: 0120-LA120-03 Software Version: N/A Product DescrVideo fluoroscopy table may contain inadequate weld on backrest bracket resulting in backrest dropping.
-
Class IIofficial
CooperVision, Inc. recalls MyDay ToricOne lot manufactured with an invalid sterilization cycle.
-
Class IIofficial
CooperVision, Inc. recalls Sofmed BreathablesOne lot manufactured with an invalid sterilization cycle.
-
Class IIofficial
CooperVision, Inc. recalls Voyant 1-Day Premium ToricOne lot manufactured with an invalid sterilization cycle.
-
Class IIofficial
Folsom Metal Products, Inc. recalls Frontier DevicesLabeling includes shelf life that has not been validated.
-
Class IIofficial
Folsom Metal Products, Inc. recalls Frontier DevicesLabeling includes shelf life that has not been validated.
-
Class IIofficial
Folsom Metal Products, Inc. recalls Frontier DevicesLabeling includes shelf life that has not been validated.
-
Class IIofficial
Folsom Metal Products, Inc. recalls Frontier DevicesLabeling includes shelf life that has not been validated.
-
Class IIofficial
Folsom Metal Products, Inc. recalls Frontier DevicesLabeling includes shelf life that has not been validated.
-
Class IIofficial
Folsom Metal Products, Inc. recalls Frontier DevicesLabeling includes shelf life that has not been validated.
-
Class IIofficial
Abbott Point Of Care Inc. recalls i-STAT CG4+ cartridge (white). List Number: 03P85-25.Lack of a 510(k) premarket clearance for the i-STAT CG4+ cartridge to reflect updated sample type for lactate and measurement ranges for pH and PO2.
-
Class IIofficial
Abbott Point Of Care Inc. recalls i-STAT CG8+ cartridge. List Number: 03P88-25. 510(k) numbers: K894914Lack of a 510(k) premarket clearance for the i-STAT CG8+, EG7+ and EG6+ cartridges to reflect updated sample type for potassium and ionized calcium and measurement ranges for pH and PO2.
-
Class IIofficial
Abbott Point Of Care Inc. recalls i-STAT EG7+ cartridge. List Number: 03P76-25.Lack of a 510(k) premarket clearance for the i-STAT CG8+, EG7+ and EG6+ cartridges to reflect updated sample type for potassium and ionized calcium and measurement ranges for pH and PO2.
-
Class IIofficial
Abbott Point Of Care Inc. recalls i-STAT EG6+ cartridge. List Number: 03P77-25.Lack of a 510(k) premarket clearance for the i-STAT CG8+, EG7+ and EG6+ cartridges to reflect updated sample type for potassium and ionized calcium and measurement ranges for pH and PO2.
-
Class IIofficial
Bard Peripheral Vascular Inc recalls Venclose digiRF GeneratorsSoftware version 3.35 of the Venclose digiRF Generator incorporates a catheter verification feature specifically designed to detect internal wiring anomalies in Venclose EVSRF Ablation Catheters prior to clinical use. This automated diagnostic check is executed immediately upon catheter connection to the generator, occurring before the procedure interface becomes accessible. When a catheter fails this verification process, the generator displays a Red X indicator on the screen without accompanying error codes, effectively disabling catheter functionality. However, BD has determined that software version 3.35 generates false positive failures due to temperature-dependent verification parameters, incorrectly flagging properly functioning Venclose EVSRF Ablation Catheters as defective when the catheter temperature is not at steady state during the check initiation.
-
Class Iofficial
Medline Industries, LP recalls Medline Kits: 1) VALVE PACK-LFThe kits contain certain lots of cannula products where the catheter may not retain its shape.
-
Class Iofficial
Boston Scientific Corporation recalls ACCOLADE SR SL (Model L300)Software to enhance Safety Architecture is available and designed to prevent initiation of Safety Mode in an ambulatory setting due to a high battery impedance state for the ACCOLADE family of devices which includes ACCOLADE, PROPONENT, ESSENTIO, and ALTRUA 2 dual chamber (DR) standard life (SL) and DR extended life (EL) pacemakers; and VISIONIST and VALITUDE cardiac resynchronization therapy pacemakers (CRT-Ps).