Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 3 M12. Model Numbers: 722063Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 3 M15. Model Number: 722064Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 5 M12. Model Number: 722227.Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 5 M20. Model Numbers: 722228Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7 B12. Model Numbers: 722067Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7 B20. Model Numbers: 722068Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7 M12. Model Numbers: 722078Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7 M20. Model Numbers: 722079Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion S. Model Number: 722285.Solid-State Drives (SSDs) that are not specified in the Medical Device File may have been installed in various PCs. These SSDs may have different performance characteristics, which may include reduced reliability over time such as loss of imaging functionality or motorized movement, a blank or black display, and/or the inability to store newly acquired images or access previously acquired images.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion RystemTwo software related issues affecting Azurion R2.2.10 Systems: 1) Potential image quality degradation that may lead to delay of therapy, procedural complications and/or inappropriate treatment and 2) Potential loss of geometry movements that may lead to delay of therapy and procedural complications
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips AzurionTwo software related issues: 1) Potential image quality degradation that may lead to delay of therapy, procedural complications and/or inappropriate treatment and 2) Potential loss of geometry movements that may lead to delay of therapy and procedural complications
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD. Model Numbers: 722026Firmware issue potentially leading to loss of geometry movements.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura under the following System Descriptions and corresponding model numbers: 1. Allura Xper FD10; MPotential Loss of imaging functionality, loss of motorized movement, or loss of data due to unauthorized Hard Disk Drives.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion under the following System Descriptions and corresponding model numbers: 1. Azurion 3 M12; ModPotential Loss of imaging functionality, loss of motorized movement, or loss of data due to unauthorized Hard Disk Drives.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips AlluraPotential Loss of imaging functionality, loss of motorized movement, or loss of data due to unauthorized Hard Disk Drives.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips MultiDiagnost Eleva with the following Model Numbers: Model # 708032 for MultiDiagnost Eleva; Model #Philips Allura Xper and MultiDiagnost-Eleva systems Hand switch button not fully releasing potentially leading to loss of imaging functionality or unintended radiation exposure and additional contrast injection
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper with the following Model Numbers: Model # 722001 for Allura Xper FD10C; Model # 722002 forPhilips Allura Xper and MultiDiagnost-Eleva systems Hand switch button not fully releasing potentially leading to loss of imaging functionality or unintended radiation exposure and additional contrast injection
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion system; System Code Description (Model Numbers): Azurion 3 M12 (722063It was identified that HDDs used in the PCs of Azurion and Allura systems may show a decrease in performance as they age, particularly beyond six years of service. Issues with an HDD may, depending on the specific system PC in which the affected HDD is installed, result in loss of imaging functionality. Additionally, in Allura systems, this may lead to loss of motorized movement, or loss of data. In some cases, a system restart may temporarily restore functionality.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura system; System Code Description (Model Numbers): Allura Xper FD10 (722003It was identified that HDDs used in the PCs of Azurion and Allura systems may show a decrease in performance as they age, particularly beyond six years of service. Issues with an HDD may, depending on the specific system PC in which the affected HDD is installed, result in loss of imaging functionality. Additionally, in Allura systems, this may lead to loss of motorized movement, or loss of data. In some cases, a system restart may temporarily restore functionality.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion systems not configured with an optional auxiliary pan handle. Includes the below product descrPotential safety issue with Philips Azurion systems, where longitudinal and transverse table movements may be impacted due to mechanical wear of the Float Tabletop control on the control module.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion system; System Code Description (Model Numbers): Azurion 3 M12 (722063)The deaeration hose in X-ray tube cooling units type CU3101, manufactured between February 2016 and May 2020, may degrade over time, potentially resulting in oil leakage. Oil leakage may affect the cooling performance of the X-ray tube. When the oil flow drops below a certain threshold, the system automatically switches to low-dose fluoroscopy and displays the message Low load fluoroscopy flavor selected: Tube cooler problem . This condition cannot be resolved by restarting the system.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura system; System Code Description (Model Numbers): Allura Xper FD10C (722001)The deaeration hose in X-ray tube cooling units type CU3101, manufactured between February 2016 and May 2020, may degrade over time, potentially resulting in oil leakage. Oil leakage may affect the cooling performance of the X-ray tube. When the oil flow drops below a certain threshold, the system automatically switches to low-dose fluoroscopy and displays the message Low load fluoroscopy flavor selected: Tube cooler problem . This condition cannot be resolved by restarting the system.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Integris-Allura system; System Code Description (Model Numbers): Integris CV Cesar-Powerpack-Visub-Nicol (7220The deaeration hose in X-ray tube cooling units type CU3101, manufactured between February 2016 and May 2020, may degrade over time, potentially resulting in oil leakage. Oil leakage may affect the cooling performance of the X-ray tube. When the oil flow drops below a certain threshold, the system automatically switches to low-dose fluoroscopy and displays the message Low load fluoroscopy flavor selected: Tube cooler problem . This condition cannot be resolved by restarting the system.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion. System Code Description (Model Number): Azurion 3 M12 (722221Potential for the bolts and plastic parts of the Cable Hose Carriers that hold the cable hose to the monitor ceiling suspension may loosen and/or break over time due to the forces applied when the monitor is moved or rotated.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips AneurysmFlow. Model Number: 001015. AneurysmFlow is a software medical device (Interventional Tool) inPotential safety issue involving the Mean Aneurysm Flow Amplitude (MAFA) ratio of AneurysmFlow (Interventional Tool). Philips has determined that the MAFA ratio does not provide reliable prognostic information regarding aneurysm occlusion following Flow Diverter Stent treatment, however despite being stated in the IUF, it is being relied on for making clinical decisions.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Vue Motion V12. Product Number: 1017979.Potential that mis-ordered frames in Vue Motion during dynamic cine runs may cause images frames to display out of sequence.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD10C; System Code: 722001;Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD10F; System Code: 722002;Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD10; System Code: (1) 722003Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD10/10; System Code: (1) 722005Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD20; System Code: (1) 722006Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD20 Biplane; System Code: (1) 722008Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD20 OR Table; System Code: (1) 722015Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD20 Biplane OR Table; System Code: (1) 722020Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls ALLURA Xper FD10 OR Table; System Code: (1) 722022Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/10; System Code: 722029;Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/20; System Code: 722038;Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/20 OR Table; System Code: 722039;Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/15; System Code: 722058;Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/15 OR Table; System Code: 722059;Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 3 M12; System Code: (1)722063Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 3 M15; System Code: (1)722064Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 B12; System Code: (1)722067Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 B20; System Code: (1)722068Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 M12; System Code: (1)722078Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 M20; System Code: (1)722079Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 5 M12; System Code: (1)722227Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 5 M20; System Code: (1)722228Philips has identified instances where X-ray imaging may not be initiated or may occur intermittently when using the wired foot switch.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 3 M12 System Model Numbers: (1) 722063Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 3 M15 System Model Numbers: (1) 722064Under certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.