Olympus Corporation of the Americas recalls EasySuite 4K Integrated Operating Room System Model/Catalog Number: EasySuite 4K- The EasySuite 4K system inclA subset of the ES4K systems do not have complete records for earth leakage testing. The earth leakage test is a series of measurements intended to confirm that the amount of electrical current flowing to the earth is within standard limits
-
Class IIofficial
Barco N.V. recalls MNA-420 ENC HDMIWe have identified a potential issue with the SFP+ module supplied by Molex (Part Number: B620050) when connected to the ETH0 slot of either the MNA-6x0 ENC HDMI or MNA-4x0 ENC HDMI. In some instances, this connection may render the first HDMI channel inaccessible, making both the channel and the respective MNA ENC unit unusable. Additionally, readings from the module become unavailable when this issue arises. Similarly, when this Molex module is connected to the ETH0 slot of an MNA-620 ENC ANA, readings may also become inaccessible.
-
Class IIofficial
Ethicon, Inc. recalls SURGIFOAM" Absorbable Gelatin Powder KitSome applicator tips from these lots had open seals.
-
Class IIofficial
Cadwell Industries Inc recalls Cascade IOMAX Cortical ModuleThere is the potential that an electroneurodiagnostic medical device insulator may be installed incorrectly which could result in arcing to patient connections resulting in potential unintended shock to the patient.
-
Class IIofficial
Siemens Healthcare Diagnostics, Inc. recalls IMMULITE 2000 Anti-TG Ab Catalog # L2KTG2 (200 Tests)The potential for falsely elevated patient sample results when using impacted lots (782, 783, 785, 786, 787, 788, 789, 790, 791, 792 and 793), of IMMULITE 2000 Anti-TG Ab.
-
Class IIofficial
Siemens Healthcare Diagnostics, Inc. recalls IMMULITE 2000 Anti-TG Ab Catalog # L2KTG6 (600 Tests)The potential for falsely elevated patient sample results when using impacted lots (785, 790, 791, and 793) of IMMULITE 2000 Anti-TG Ab.
-
Class IIofficial
Stryker Neurovascular recalls Trevo XP ProVue Retriever 4 x 20Neurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Stryker Neurovascular recalls Trevo ProVueNeurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Stryker Neurovascular recalls Trevo Pro 14 MicrocatheterNeurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Stryker Neurovascular recalls Trevo NXT ProVue 3 x 32Neurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Stryker Neurovascular recalls Trevo Trak 21 MicrocatheterNeurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Stryker Neurovascular recalls FlowGate2 8F x 85cmNeurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Stryker Neurovascular recalls DAC 044 115cmNeurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Stryker Neurovascular recalls Synchro .014"guide wireNeurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
-
Class IIofficial
Mckesson Medical-Surgical Inc. Corporate Office recalls Coviden Monoject 60ml Syringe Luer-Lock Tip-used to inject fluid into or withdraw fluids from the body MMS CatQuarantined product was inadvertently distributed
-
Class IIofficial
Murata Vios, Inc. recalls muRata Vios Monitoring System Model 2050; bedside cardiac monitorDuring the set-up and workflow to begin Vios monitoring, it has been noticed that patient vital signs and ECG waveforms can become distorted and will flicker or flash very fast. This issue only occurs on the Central Station Monitor (CSM) in the patient tiles view and is not seen at any other point during patient monitoring & not on the Bedside Monitor.
-
Class IIofficial
Philips North America Llc recalls Ingenia 1.5T with Evolution Upgrade 1.5T - Magnetic Resonance (MR) systems are Medical Electrical Systems indiPhilips Ingenia Evolution systems with software R5.7.1 may not provide warning for low ventilation setting which may lead to increase in body temperature or burning sensation
-
Class IIofficial
Philips North America Llc recalls Ingenia 3.0T with Evolution Upgrade 3.0T - - Magnetic Resonance (MR) systems are Medical Electrical Systems inPhilips Ingenia Evolution systems with software R5.7.1 may not provide warning for low ventilation setting which may lead to increase in body temperature or burning sensation
-
Class IIofficial
Mirion Technologies (Capintec), Inc. recalls Captus 4000e Thyroid Uptake System. Intended to be used to perform Thyroid UptakesComplaints of unexpected detachment of the collimator have been reported.
-
Class IIofficial
Mirion Technologies (Capintec), Inc. recalls Captus 4000e Thyroid Uptake System with Well. Intended to be used to perform Thyroid UptakesComplaints of unexpected detachment of the collimator have been reported.
-
Class IIofficial
Mirion Technologies (Capintec), Inc. recalls Captus 4000e Thyroid Uptake System with Well and 2 inch shielding. Intended to be used to perform Thyroid UptaComplaints of unexpected detachment of the collimator have been reported.
-
Class IIofficial
Alcon Research LLC recalls 20 Gauge V-Lance Knife Model/Catalog Number: 8065912001 Software Version: N/A Product Description: OphthalmicAlcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Corneal/Scleral V-Lance Ophthalmic knives.
-
Class IIofficial
Alcon Research LLC recalls ClearCut Sideport Knife Dual Bevel 1.2mm Angled Model/Catalog Number: 8065921541 Software Version: N/A ProductAlcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Corneal/Scleral V-Lance Ophthalmic knives.
-
Class IIofficial
Alcon Research LLC recalls ClearCut S Safety Sideport Knife 1.0mm Dual Bevel Model/Catalog Number: 8065771540 Software Version: N/A ProduAlcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Corneal/Scleral V-Lance Ophthalmic knives.
-
Class IIofficial
Alcon Research LLC recalls ClearCut S Safety Sideport Knife 1.2mm Dual Bevel Model/Catalog Number: 8065771541 Software Version: N/A ProduAlcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Corneal/Scleral V-Lance Ophthalmic knives.
-
Class IIofficial
MEDLINE INDUSTRIES, LP - Northfield recalls MEDLINE LUER LOCK DISPOSABLE SYRINGE WITHOUT NEEDLEIt has been identified that testing documentation does not support that the syringes can successfully deliver accurate volumes across the full range of their claimed graduated capacity and may pose a risk to patient health.
-
Class IIofficial
MEDLINE INDUSTRIES, LP - Northfield recalls MEDLINE LUER SLIP DISPOSABLE SYRINGE WITHOUT NEEDLEIt has been identified that testing documentation does not support that the syringes can successfully deliver accurate volumes across the full range of their claimed graduated capacity and may pose a risk to patient health.
-
Class IIofficial
Wondfo USA Co Ltd recalls Preview Strep AWondfo USA has identified unauthorized distribution of the Preview Strep A Test Kit. Unauthorized distribution of this device would include sales and distribution of this test for at-home use, non-prescription use, over-the-counter use, or direct-to-consumer customers.
-
Class IIofficial
Wondfo USA Co Ltd recalls Clarity and Clarity Diagnostics LLCWondfo USA has identified unauthorized distribution of the Preview Strep A Test Kit. Unauthorized distribution of this device would include sales and distribution of this test for at-home use, non-prescription use, over-the-counter use, or direct-to-consumer customers.
-
Class IIofficial
Wondfo USA Co Ltd recalls Streptococcal A rapid test kitsWondfo USA has identified unauthorized distribution of the Preview Strep A Test Kit. Unauthorized distribution of this device would include sales and distribution of this test for at-home use, non-prescription use, over-the-counter use, or direct-to-consumer customers.
-
Class IIofficial
Wondfo USA Co Ltd recalls Independent Medical Co-op Inc.Wondfo USA has identified unauthorized distribution of the Preview Strep A Test Kit. Unauthorized distribution of this device would include sales and distribution of this test for at-home use, non-prescription use, over-the-counter use, or direct-to-consumer customers.
-
Class IIofficial
Wondfo USA Co Ltd recalls Streptococcal A rapid test kitsWondfo USA has identified unauthorized distribution of the Preview Strep A Test Kit. Unauthorized distribution of this device would include sales and distribution of this test for at-home use, non-prescription use, over-the-counter use, or direct-to-consumer customers.
-
Class IIofficial
GE Medical Systems Information Technologies Inc recalls Prucka 3 Amplifier Model #P1801PA used with CardioLab AltiX electrophysiology recording system and ComboLab AlCapacitors in certain Prucka 3 Amplifiers used with CardioLab / ComboLab systems could fail resulting in transient oscillations on the display and inability to view surface and intracardiac ECG waveforms.
-
Class IIofficial
Philips North America Llc recalls Patient Information Center iX and Patient Information Center iX ExpandEvent Catalog information does not save when copied and transferred from one unit to another.
-
Class IIofficial
Beckman Coulter, Inc. recalls Beckman Coulter Dxl 9000 Access Immunoassay AnalyzerWhen the DxI 9000 Access Immunoassay Analyzer with system software version 1.16.2 and prior is configured to automatically request a calibration order, the instrument can process the order with expired calibrator material. If the calibration curve is generated with an expired calibration material lot, this may lead to a hazardous situation of erroneously high or low patient results reported to the physicians.
-
Class Iofficial
OptumHealth Care Solutions LLC recalls Optum Nimbus II PlusNimbus II Plus, Infusion Pump Systems, manufactured by InfuTronix, are being removed the from the market due to multiple potential failure modes, including battery failure, upstream occlusion, system errors, drug product leakage, high or low flow rate, or damaged pump housing.
-
Class IIofficial
Boston Scientific Neuromodulation Corporation recalls Vercise Genus Deep Brain Stimulation (DBS) Implantable Pulse Generator IPG: R16 IPG KITDeep Brain Stimulation (DBS) Implantable Pulse Generator (IPG) may experience routine system check during IPG charging, which may cause device reset. The device reset could lead transient loss of stimulation; patients may experience undesired sensations, transient worsening of movement disorder symptoms, which may lead patient to request surgical intervention for replacement or revision.
-
Class IIofficial
Stryker Neurovascular recalls The Synchro Neuro Guidewires are a steerable guidewire family with a shapeable tip. The outside diameter of thStryker Neurovascular has observed an increased frequency of PTFE coating damage occurring on the Synchro Guidewires that may be caused by the practice of backloading the guidewire through the optional introducer accessory. This issue is limited to certain lots of the Synchro Guidewire that contain an older version of the introducer accessory. Due to variation in the manufacturing process of the supplier of the introducer accessory, certain lots of introducers have sharper than intended edges that can peel off the PTFE coating when physicians use a technique known as backloading. Users with impacted product in their inventory are cautioned not to use this backloading technique.
-
Class IIofficial
Stryker Neurovascular recalls The Synchro SELECT Guidewires are a steerable guidewire family with a shapeable tip and are available in straiStryker Neurovascular has observed an increased frequency of PTFE coating damage occurring on the Synchro Guidewires that may be caused by the practice of backloading the guidewire through the optional introducer accessory. This issue is limited to certain lots of the Synchro Guidewire that contain an older version of the introducer accessory. Due to variation in the manufacturing process of the supplier of the introducer accessory, certain lots of introducers have sharper than intended edges that can peel off the PTFE coating when physicians use a technique known as backloading. Users with impacted product in their inventory are cautioned not to use this backloading technique.
-
Class IIofficial
Stryker Neurovascular recalls The Synchro2 Guidewires are a steerable guidewire family with a shapeable tip and are available in straight anStryker Neurovascular has observed an increased frequency of PTFE coating damage occurring on the Synchro Guidewires that may be caused by the practice of backloading the guidewire through the optional introducer accessory. This issue is limited to certain lots of the Synchro Guidewire that contain an older version of the introducer accessory. Due to variation in the manufacturing process of the supplier of the introducer accessory, certain lots of introducers have sharper than intended edges that can peel off the PTFE coating when physicians use a technique known as backloading. Users with impacted product in their inventory are cautioned not to use this backloading technique.
-
Class IIofficial
Bd Switzerland Sarl recalls Alaris Pump Infusion Set Low Sorbing Tubing (PE Lined) Back Check Valve 2 SmartSite Y Sites REF 10013072 TubinDue to infusion set tubing drip chamber becoming detached from the tubing potentially causing delays in treatment, or unintentionally exposing users to harsh infusates.
-
Class IIofficial
Olympus Corporation of the Americas recalls OES 4000 HysteroscopeThe required leakage test was not performed following of a re-work for a non-conformity. This could potentially result in liquid ingress into the eyepiece and cause a foggy image.
-
Class IIofficial
Exactech, Inc. recalls OPTETRAK Three Peg PatellaExactech is recalling all affected UHMWPE (ultra-high molecular weight polyethylene) knee patella components packaged in out of specification vacuum bags.
-
Class IIofficial
Exactech, Inc. recalls OPTETRAK One Peg PatellaExactech is recalling all affected UHMWPE (ultra-high molecular weight polyethylene) knee patella components packaged in out of specification vacuum bags.
-
Class IIofficial
Exactech, Inc. recalls OPTETRAK Inset PatellaExactech is recalling all affected UHMWPE (ultra-high molecular weight polyethylene) knee patella components packaged in out of specification vacuum bags.
-
Class IIofficial
Exactech, Inc. recalls OPTETRAKExactech is recalling all affected UHMWPE (ultra-high molecular weight polyethylene) knee patella components packaged in out of specification vacuum bags.
-
Class IIofficial
Beckman Coulter, Inc. recalls DxI 9000 Access Immunoassay AnalyzerBeckman Coulter is recalling their DxI 9000 Access Immunoassay Analyzers, an in vitro diagnostic device used for the quantitative, semi-quantitative, or qualitative determination of various analyte concentrations found in human body fluids, by correction. The reason for the recall is: Beckman Coulter has determined that the DxI 9000 Access Immunoassay analyzer accepts calibrator values scanned from multiple calibrator cards when an operator configures a new calibrator lot. The analyzer accepts the calibrator lot values from any scanned calibrator card, regardless of the assay test code or calibrator material lot number. The software is not validating the integrity of each calibrator barcode scanned to ensure they are all from the same calibrator card. This includes all software versions and all DxI 9000 instruments that are currently in the field. This issue does not impact calibrator material with 2D calibrator card barcodes. This may cause a failed calibration curve. The health risk to patients is dependent upon the analytes that could be impacted by the error, to include receiving delayed or erroneous results. The issue was identified by Beckman Coulter while conducting a field action on DxI 9000 Access Immunoassay Analyzers.
-
Class IIofficial
MED-EL Elektromedizinische Gereate, Gmbh recalls Mi1250 SYNCHRONY 2A small number of devices may have a higher probability of a crack within the internal electronics substrate which could result in a non-functional device.
-
Class IIofficial
Nrt X-ray A/s recalls Intelli-C: Right side suspended TabletopX-ray system C-arm may experience uncontrolled motion if 1) AC motor controller firmware has a faulty setting, 2) the Motor/gear assembly is worn, 3) CAT movement is driven at maximum speed and angulated more than 75 deg. from vertical, and 4) the emergency stop or touch guard is activated during the breaking sequence, which could lead to the C-arm hitting the patient or operator.
-
Class IIofficial
Yamaha Motor Corporation recalls Yamaha Surface Mounter YR seriesNon-medical laser products which were determined to not be in compliance with 21 C.F.R. ¿ 1010.2 in that they currently do not bear the required certification label.