Class IIofficial
Smith & Nephew Inc. recalls ROTATION MEDICAL TENDON STAPLES (8) (narrow indication)-Intended for fixation of prosthetic material to soft tProduct packaging process may result in an improper or incomplete seal of the outer foil pouch surrounding the inner Tyvek pouch, compromising product sterility
-
Class IIofficial
Seer Medical Pty Ltd recalls Seer Home System is an ambulatory electroencephalograph (EEG) system intended for at-home use for extended EEGDuring CAPA investigations of sight production inconsistencies, it was highlighted that previous Electromagnetic Compatibility (EMC) assessments related to RF radiated emissions may not be reasonably equivalent to the current product due to design changes in the system. A new CAPA was opened to investigate the radiated emissions compliance issues. - Seer Home Systems distributed and retained in the field were not compliant with Electromagnetic Compatibility (EMC) testing according to IEC 60601-1-2 - Seer Home Systems, including accessories, were manufactured and distributed without application of proper design change and manufacturing controls - Seer Home Systems were distributed with labeling deficiencies
-
Class IIofficial
Merit Medical Systems, Inc. recalls Prelude Sheath Introducer 7.5F7F sheath introducers labeled as 7.5F
-
Class IIofficial
Merit Medical Systems, Inc. recalls Custom Procedure Kit7F sheath introducers labeled as 7.5F
-
Highest. risk
Triple E Recreational Vehicles: Incorrectly Routed Propane Line May LeakA propane leak in the presence of an ignition source increases the risk of a fire.
-
Highest. risk
Blue Bird Body Company: Improperly Coated Fuel Lines May LeakA fuel leak in the presence of an ignition source increases the risk of a fire.
-
Highest. risk
Blue Bird Body Company: Improperly Coated Fuel Lines May LeakA fuel leak in the presence of an ignition source increases the risk of a fire.
-
Mediumest. risk
Livewire Ev, LLC: High Voltage Fuse May Cause a Loss of Drive PowerUnexpected loss of drive power increases the risk of a crash.
-
Mediumest. risk
Motiv Power Systems: HV Battery Shutdown Can Cause Loss of Drive PowerThe shutdown of the HV batteries can cause a loss of steering and brake power assist, and drive power, increasing the risk of a crash.
-
Mediumest. risk
Motiv Power Systems: Damage to Wires can Cause Loss of Drive PowerA loss of drive power increases the risk of a crash.
-
Highest. risk
Ford Motor Company: Engine Failure May Cause FireAn engine compartment fire increases the risk of injury.
-
Class IIofficial
Direct Rx recalls Ibuprofen 800mgFailed Impurities/Degradation Specifications: Product failed impurity specifications at the 18-month stability testing.
-
Class Iofficial
Prime Food Processing Corp. recalls Prime Food brand Steam Bun with Egg Custard Added; 10pcs/pack; NET WT. 20 oz (1lb.4 oz) 568g; KEEP FROZEN; INGProducts may contain undeclared sesame
-
Class Iofficial
Prime Food Processing Corp. recalls Prime Food brand Steam Bun with Egg Custard & Coconut Added; 10pcs/pack; NET WT. 20 oz (1lb.4 oz) 568g; KEEP FProducts may contain undeclared sesame
-
Class IIofficial
Physio-Control, Inc. recalls STERILIZABLE INTERNAL DEFIBRILLATION PADDLES REF LP20 STERILIZABLE INTERNAL DEFIBRILLATION PADDLES REF LP15 DeDue to customer complaints and out of box failures, the firm is conducting a voluntary recall as a result of product failures (cracks and over-molding separation of the sterilizable internal defibrillation paddles.
-
Class IIofficial
Murata Vios, Inc. recalls Vios Monitoring System Bedside Monitor Model BSM2050Batteries may deplete over time while not in use if devices are stored without being plugged in to wall outlet. Depleted batteries may lead to tablet connectivity issues.
-
Class IIofficial
Wipro GE Healthcare Private Ltd. recalls GE Giraffe WarmerGE HealthCare has become aware that complete electrical safety testing was not conducted during manufacturing of certain Giraffe and Panda iRes Warmers. There are multiple electrical safety protections included in the product design. However, because the electrical safety testing in manufacturing was incomplete for these devices, there is the potential for leakage current to exceed IEC 60601 limits.
-
Class IIofficial
Wipro GE Healthcare Private Ltd. recalls GE Panda iRES WarmerGE HealthCare has become aware that complete electrical safety testing was not conducted during manufacturing of certain Giraffe and Panda iRes Warmers. There are multiple electrical safety protections included in the product design. However, because the electrical safety testing in manufacturing was incomplete for these devices, there is the potential for leakage current to exceed IEC 60601 limits.
-
Mediumest. risk
Cruise LLC: Software May Cause Unexpected BrakingUnexpected braking can increase the risk of a crash.
-
Mediumest. risk
Ford Motor Company: Loss of Drive Power from Undetected Low BatteryAn undetected low battery charge can result in a loss of electrical accessories such as hazard lights, or cause a loss of drive power, increasing the risk of a crash.
-
Mediumest. risk
Ford Motor Company: Steering Column Assembled with Incorrect BoltA loss of steering control can increase the risk of a crash.
-
Mediumest. risk
Mercedes-Benz USA, LLC: Incorrectly Routed Brake Hose May LeakA brake fluid leak can cause a loss of brakes and increase the risk of a crash.
-
Mediumest. risk
Ford Motor Company: Rear Suspension Knuckles May FailA loss of vehicle handling and steering control increases the risk of a crash.
-
Mediumest. risk
Ford Motor Company: Windshield Wiper Motor May FailInoperative windshield wipers can reduce visibility in certain conditions, increasing the risk of a crash.
-
Mediumest. risk
Ford Motor Company: Power Windows May Pinch/FMVSS 118A closing window may exert excessive force by pinching a driver or passenger before retracting, increasing the risk of injury.
-
Mediumest. risk
SMEG USA Recalls Refrigerators Due to Injury HazardThe refrigerator door can detach and fall off, posing an injury hazard.
-
Highest. risk
Samsung Recalls Slide-In Electric Ranges Due to Fire HazardFront-mounted knobs on the ranges can be activated by accidental contact by humans or pets, posing a fire hazard.
-
Mediumest. risk
Chem-Pak Recalls Finger-Ease Guitar String Lubricants Due to Skin Irritation HazardThe recalled guitar string lubricant contains a contaminant, posing a risk of skin irritation.
-
Class IIofficial
Teva Pharmaceuticals USA, Inc recalls Testosterone GelSuperpotent Drug
-
Class IIofficial
Preferred Pharmaceuticals, Inc. recalls Ibuprofen TabletsFailed Impurities/Degradation Specifications - at 18-month Stability testing
-
Class IIofficial
Kester Foods LLC recalls Yummy Monkey Organics Butter & Yeast PopcornLabel declares butter and ghee but does not declare milk.
-
Class IIofficial
Kester Foods LLC recalls Yummy Monkey Organics Real Movie Theater PopcornLabel declares butter and ghee but does not declare milk.
-
Class IIofficial
Epilog Laser Corp. recalls Fusion Pro 24a. A small number of Fusion Pro 24 units were released with an incorrectly placed Interlock device. As a result, the system can be operated with the front-loading door in an open position. b. Fails to comply with Class 2 designation, indicated in Part 6 of Laser Product Report. An incorrectly placed Interlock device can allow Class 4 laser radiation fields during operation.
-
Class IIofficial
Orthoscan, Inc. recalls Ziehm Solo. Digital Mobile C-armZiehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
-
Class IIofficial
Orthoscan, Inc. recalls Ziehm Solo FD. Interventional fluoroscopic x-ray systemZiehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
-
Class IIofficial
Orthoscan, Inc. recalls Ziehm Vision systemZiehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
-
Class IIofficial
Orthoscan, Inc. recalls Ziehm Vision FD. Interventional fluoroscopic x-ray systemZiehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
-
Class IIofficial
Orthoscan, Inc. recalls Ziehm Vision R. Iterventional fluoroscopic x-ray systemZiehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
-
Class IIofficial
Orthoscan, Inc. recalls Ziehm Vision RFD. Interventional fluoroscopic x-ray systemZiehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
-
Class IIofficial
Orthoscan, Inc. recalls Ziehm Vision RFD 3D. Interventinoal fluoroscopic x-ray systemZiehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching element in the hand switch. A defective switching element may then potentially initiate unintended radiation of the connected mobile X-ray unit.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper systems (R8.1 with Poly-G Stand) Interventional Fluoroscopic X-Ray SystemA half-threaded bolt was included in the LTE kits instead of the correct full-threaded bolt.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls Blood Pressure Module BPM3 TM-2917B (Spare Part Numbers 191378 or 191389) with firmware version S005 installedMachines equipped with BPM3 Blood Pressure Modules (Blood pressure monitor TM-2917B with firmware version S005) will not record Blood Pressure measurements and does not alarm if the cuff tubing is kinked close to the cuff.
-
Class IIofficial
Zimmer GmbH recalls Biolox Option Taper SleeveMislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etching as either STD or -6
-
Class IIofficial
Zimmer GmbH recalls Biolox Option Taper SleeveMislabeled: Incorrect sleeve in the packaging. The outer packaging is labeled as a standard neck sleeve, however, the product within the box is a -6mm neck sleeve, and vice versa. The neck of the sleeve can be identified by the device etching as either STD or -6
-
Class Iofficial
Datascope Corp. recalls CARDIOSAVE HYBRID INTRA-AORTIC BALLOON PUMP (IABP). Electromechanical system used to inflate and deflate intraFirm has developed a software correction (Revision D.00) outside the US to mitigate product problems that pose a risk of hemodynamic instability and failure of transmission of clinical data in Cardiosave Hybrid and Cardiosave Rescue Intra-Aortic Balloon Pump devices.
-
Class Iofficial
Datascope Corp. recalls CARDIOSAVE RESCUE INTRA-AORTIC BALLOON PUMP (IABP). Electromechanical system used to inflate and deflate intraFirm has developed a software correction (Revision D.00) outside the US to mitigate product problems that pose a risk of hemodynamic instability and failure of transmission of clinical data in Cardiosave Hybrid and Cardiosave Rescue Intra-Aortic Balloon Pump devices.
-
Class Iofficial
Datascope Corp. recalls CARDIOSAVE HYBRID INTRA-AORTIC BALLOON PUMP (IABP). Electromechanical system used to inflate and deflate intraFirm has developed a software correction (Revision D.01) for outside the US to mitigate product problems that pose a risk of hemodynamic instability and failure of transmission of clinical data in Cardiosave Hybrid and Cardiosave Rescue Intra-Aortic Balloon Pump devices.
-
Class Iofficial
Datascope Corp. recalls CARDIOSAVE RESCUE INTRA-AORTIC BALLOON PUMP (IABP). Electromechanical system used to inflate and deflate intraFirm has developed a software correction (Revision D.01) for outside the US to mitigate product problems that pose a risk of hemodynamic instability and failure of transmission of clinical data in Cardiosave Hybrid and Cardiosave Rescue Intra-Aortic Balloon Pump devices.
-
Class IIofficial
B. Braun Medical, Inc. recalls AET36 ANESTH EXT SET - Anesthesia Extension Set - Normally Closed Dual ManifoldPotential for product leakage from the Spin Lock Connector on the distal end of the device due to the migration of excess solvent during the assembly process.
-
Class IIofficial
GE Healthcare GmbH recalls ViewPoint; systemThe National Institute of Standards and Technology (NIST) has identified in the National Vulnerability Database (NVD) that NexGen Healthcare Mirth Connect, prior to version 4.4.1, has a potential vulnerability allowing the deserialization of untrusted data (CVE-2023-43208). Mirth products may have been installed and configured with your ViewPoint / ViewPoint 6 system by GE HealthCare. This vulnerability could allow a malicious actor to access the system and potentially manipulate patient data.