Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 Biplane; Catalog numbers: (1) 722008Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 Biplane OR Table; Catalog numbers: (1) 722020Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20 OR Table; Catalog numbers: (1) 722023Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/10; Catalog numbers: 722029Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/15; Catalog numbers: 722058Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD20/20; Catalog numbers: 722038Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Allura CV20; Catalog numbers: 722031Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Allura Xper FD10C; Catalog number: 722001Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 3 M12; Catalog numbers: (1) 722063Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 3 M15; Catalog numbers: (1) 722064Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 5 M12; Catalog numbers: (1) 722227Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 5 M20; Catalog numbers: (1) 722228Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 B12; Catalog numbers: (1) 722067Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 B20; Catalog numbers: (1) 722068Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 M12; Catalog numbers: (1) 722078Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 M20; Catalog numbers: (1) 722079Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class Iofficial
Philips Medical Systems Nederland B.v. recalls Cardio Vascular-Allura Centron; Catalog number: 722400 (OUS ONLY).Possibility of the patient falling from the table related to the mattress used on the patient table.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper Systems (R7.6-R8.1). Labeled as the following: 1. Allura Xper FD10Potential safety issues in Allura Xper R7.6- R8.1 systems where the Lifetime Extension (LTE) kit is not installed in a timely manner. Root cause is under investigation, but the recall reason is listed as for systems over 10 years of life with LTE kits are experiencing propeller motor clamping bolt and x-ray tube locking bolt breaks. If this happens, it may cause erratic C-arm movements and potential collision with patients or bystanders, or detection of a false collisions and subsequent blocked movement of the c-arm. Movement may also cause image noise and black area on the x-ray image, and possible need to expose the patient to additional unnecessary radiation during re-examination.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Zenition 50Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Zenition 70Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls System Code Name: 722282 Azurion 7 M20 722281 Azurion 5 M20 722236 Azurion 7 B20 722235 Azurion 7 B12 722234 APotential Detachment of the Cable Hose Carrier (due to broken plastic and/or bolts) which May Result in Parts Falling and/or Part of the Cable Hose Dropping, and result in injury.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls System Name: 722059 Allura Xper FD20/15 OR Table 722058 Allura Xper FD20/15 722039 Allura Xper FD20/20 OR TablPotential Detachment of the Cable Hose Carrier (due to broken plastic and/or bolts) which May Result in Parts Falling and/or Part of the Cable Hose Dropping, and result in injury.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls System Name: 722044 INTEGRIS Allura 15-12 (biplane) 722030 Integris CV Cesar-Powerpack-Visub-Nicol 722021 INTEPotential Detachment of the Cable Hose Carrier (due to broken plastic and/or bolts) which May Result in Parts Falling and/or Part of the Cable Hose Dropping, and result in injury.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls System Name: 708038 MultiDiagnost Eleva with Flat Detector 708037 MultiDiagnost Eleva with Flat Detector 70803Potential Detachment of the Cable Hose Carrier (due to broken plastic and/or bolts) which May Result in Parts Falling and/or Part of the Cable Hose Dropping, and result in injury.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper systems (R8.1 with Poly-G Stand) Interventional Fluoroscopic X-Ray SystemA half-threaded bolt was included in the LTE kits instead of the correct full-threaded bolt.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7M20 systems with FlexArm ceiling-mounted systemThe motorized longitudinal movement of the FlexArm stand may be inconsistent (not smooth) and eventually may become unavailable. This issue is due to grease leakage from the bearings and/or anti-corrosion oil applied on the bearings, because of which the lubrication on the ceiling rail may be excessive, reducing the friction between the rails and the friction wheel.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion Interventional Fluoroscopic X-ray System with Software Version Number: R1.0Potential Loss of Imaging (X-ray) Functionality and/or Longer Time to Perform Cold Restart
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper FD20 system with an ADN7NT patient table. Model Number: 722012When Software upgrade 8.1.100 is installed on an Allura Xper with an AD7NT (non tilt) table, the pivot brake does not engage. This issue may cause unexpected movements of the table.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper FD10 system with an ADN7NT patient table. Model Number: 722010When Software upgrade 8.1.100 is installed on an Allura Xper with an AD7NT (non tilt) table, the pivot brake does not engage. This issue may cause unexpected movements of the table.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper FD20 Biplane system with an ADN7NT patient table. Model Number: 722013When Software upgrade 8.1.100 is installed on an Allura Xper with an AD7NT (non tilt) table, the pivot brake does not engage. This issue may cause unexpected movements of the table.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Interventional Hemodynamic Application R.1.2XPotential for pressure wave data synchronization from two devices may not be correct.
-
Class IIofficial
Philips Medical Systems Nederland B.V. recalls Philips IntelliSpace Cardiovascular softwareStudy data is not able to be archived, copied, or exported with the cardiovascular software version.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 3 with a Certeray generator -To perform image guidance in diagnosticGenerator may fail due to a potential short circuit in the Printed Circuit Board Assembly (PCBA) in PoInt EVR (Power Invertor). If a short circuit occurs, it will cause the fuses to trip and the system will become non-functional due to power loss, resulting in a potential delay of procedure or termination of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 5 with a Certeray generator-To perform image guidance in diagnosticGenerator may fail due to a potential short circuit in the Printed Circuit Board Assembly (PCBA) in PoInt EVR (Power Invertor). If a short circuit occurs, it will cause the fuses to trip and the system will become non-functional due to power loss, resulting in a potential delay of procedure or termination of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 with a Certeray generator-To perform image guidance in diagnosticGenerator may fail due to a potential short circuit in the Printed Circuit Board Assembly (PCBA) in PoInt EVR (Power Invertor). If a short circuit occurs, it will cause the fuses to trip and the system will become non-functional due to power loss, resulting in a potential delay of procedure or termination of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper Interventional Fluoroscopic X-ray SystemsFramegrabber card may not perform as intended. Monitor may show no viewports, or show one or more viewports may show no image, a distorted image, or a frozen image. Switching between viewports on the monitor may not be possible. Issue may result in delay of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion Interventional Fluoroscopic X-ray SystemsFramegrabber card may not perform as intended. Monitor may show no viewports, or show one or more viewports may show no image, a distorted image, or a frozen image. Switching between viewports on the monitor may not be possible. Issue may result in delay of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper Interventional Fluoroscopic X-ray SystemsDisk Bay may not perform as intended. System may stop functioning and imaging may not be possible, resulting in delay of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion Interventional Fluoroscopic X-ray SystemsDisk Bay may not perform as intended. System may stop functioning and imaging may not be possible, resulting in delay of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Allura Xper Interventional Fluoroscopic X-ray SystemsDual In-Line Memory Modules (DIMMs) may not perform as intended. System may stop functioning and imaging may not be possible, resulting in delay of procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion systemSystem may exhibit a loss of imaging functionality and data due to an issue which can cause the system to continuously restart. If the issue occurs during a procedure, there may be a delay and/or abortion of the procedure.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 M20 FlexArm system (Software version R2.x) with Maquet Magnus Table (Software version 05.02.12)Loss of connectivity between the FlexArm and the Table due to a software issue.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Azurion 7 M20 FlexArm system (Software version R2.x) with Maquet Magnus Table (Software version 05.02.12)Loss of connectivity between the FlexArm and the Table due to a software issue related to the date/time format. This connection issue leads to a loss of movement of the arm or table.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 3M12During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 3M15During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 5M12During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 5M20During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7B12/12During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7B20/15During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.
-
Class IIofficial
Philips Medical Systems Nederland B.v. recalls Philips Azurion 7M12During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.