All recalls
Every recall from CPSC, FDA, USDA and NHTSA, newest first. Each one links to the agency's official notice. Looking for one product? Check a product.
9,374 recalls · page 100 of 188
-
Class IIofficial
Pentax of America Inc recalls PENTAX Medical Video Upper GI Scope-Intended to provide optical visualization of (via a video monitor)During endoscopic procedures using a combination of the video processor EPK-i8020c and the i20c series video endoscope, the observed image can become reddish or dark (1.8%). Users have observed smoke-like steam and noted that the light guide at the tip is hot during use / after the endoscope is removed from the patient, and may cause thermal injury to the patient's mucous membranes.
-
Class IIofficial
Pentax of America Inc recalls Pentax Medical Video Processor- Intended to be used with PENTAX Medical endoscopesDuring endoscopic procedures using a combination of the video processor EPK-i8020c and the i20c series video endoscope, the observed image can become reddish or dark (1.8%). Users have observed smoke-like steam and noted that the light guide at the tip is hot during use / after the endoscope is removed from the patient, and may cause thermal injury to the patient's mucous membranes.
-
Class IIofficial
Stryker Corporation recalls Stryker CinchLock Flex Knotless Anchor with Inserter and SutureIncrease in complaints concerning "pullwire" breakage that may result in the broken pullwire remaining in the anchor implant body after deployment.
-
Class IIofficial
GE Medical Systems, LLC recalls Definium 656HD & Discovery XR656HD (GTINs: 00840682138598The user can continue to take the next exposure after reaching the Automatic Exposure Control (AEC) limit, without taking any further actions to acknowledge or adjust exposure techniques. In all cases, a message still appears on the screen when the AEC limit is reached.
-
Class IIofficial
GE Medical Systems, LLC recalls Discovery XR656HD. X-Ray imaging system.The user can continue to take the next exposure after reaching the Automatic Exposure Control (AEC) limit, without taking any further actions to acknowledge or adjust exposure techniques. In all cases, a message still appears on the screen when the AEC limit is reached.
-
Class IIofficial
GE Medical Systems, LLC recalls Discovery XR656 HD. X-Ray imaging system.The user can continue to take the next exposure after reaching the Automatic Exposure Control (AEC) limit, without taking any further actions to acknowledge or adjust exposure techniques. In all cases, a message still appears on the screen when the AEC limit is reached.
-
Class IIofficial
GE Medical Systems, LLC recalls Optima XR646 HD. X-Ray imaging system.The user can continue to take the next exposure after reaching the Automatic Exposure Control (AEC) limit, without taking any further actions to acknowledge or adjust exposure techniques. In all cases, a message still appears on the screen when the AEC limit is reached.
-
Class IIofficial
Dexcom, Inc. recalls Dexcom G6Under very rare situations, the Dexcom G6 touchscreen receiver may not provide high or low glucose alarms/alerts as designed, which can result in two different conditions. First, if a receiver operating system .net error occurs when an alarm/alert should be triggered, the initial alarm/alert will not be delivered until a subsequent alarm/alert is triggered. At that time, the initial alarm/alert is delivered, but not the second one. Alarm/alerts will continue to be delayed and be one alarm/alert behind, causing delayed alarm/alerts until the receiver is reset. This condition could result in the missed detection of a hyperglycemic or hypoglycemic event. Second, a single EGV reading may be delayed for 5 minutes after the initial .net operating system error. If the user receives a single EGV reading delayed by 5 minutes, the delay is not expected to cause user harm.
-
Class IIofficial
Dexcom, Inc. recalls Dexcom G6Under very rare situations, the Dexcom G6 touchscreen receiver may not provide high or low glucose alarms/alerts as designed, which can result in two different conditions. First, if a receiver operating system .net error occurs when an alarm/alert should be triggered, the initial alarm/alert will not be delivered until a subsequent alarm/alert is triggered. At that time, the initial alarm/alert is delivered, but not the second one. Alarm/alerts will continue to be delayed and be one alarm/alert behind, causing delayed alarm/alerts until the receiver is reset. This condition could result in the missed detection of a hyperglycemic or hypoglycemic event. Second, a single EGV reading may be delayed for 5 minutes after the initial .net operating system error. If the user receives a single EGV reading delayed by 5 minutes, the delay is not expected to cause user harm.
-
Class IIofficial
Dexcom, Inc. recalls Dexcom G6Under very rare situations, the Dexcom G6 touchscreen receiver may not provide high or low glucose alarms/alerts as designed, which can result in two different conditions. First, if a receiver operating system .net error occurs when an alarm/alert should be triggered, the initial alarm/alert will not be delivered until a subsequent alarm/alert is triggered. At that time, the initial alarm/alert is delivered, but not the second one. Alarm/alerts will continue to be delayed and be one alarm/alert behind, causing delayed alarm/alerts until the receiver is reset. This condition could result in the missed detection of a hyperglycemic or hypoglycemic event. Second, a single EGV reading may be delayed for 5 minutes after the initial .net operating system error. If the user receives a single EGV reading delayed by 5 minutes, the delay is not expected to cause user harm.
-
Class IIofficial
Hiossen Inc. recalls ET Rigid Abutment (Mini) Size 4.5D 1.0G/H 5.0H - Intended for use with a dental implant to provide support forPatient chart stickers provided inside the packaging may incorrectly identify ET Rigid Abutments as Regular version whereas the actual product is a Mini version; and identify the ET Multi Abutments as Mini version whereas the actual product is a Regular version
-
Class IIofficial
Hiossen Inc. recalls ET Rigid Abutment (Mini) SIze: 4.5D 3.0G/H 7.0H - Intended for use with a dental implant to provide support foPatient chart stickers provided inside the packaging may incorrectly identify ET Rigid Abutments as Regular version whereas the actual product is a Mini version; and identify the ET Multi Abutments as Mini version whereas the actual product is a Regular version
-
Class IIofficial
Hiossen Inc. recalls ET Rigid Abutment (Mini) SIze: 4.5D 4.0G/H 4.0H - Intended for use with a dental implant to provide support foPatient chart stickers provided inside the packaging may incorrectly identify ET Rigid Abutments as Regular version whereas the actual product is a Mini version; and identify the ET Multi Abutments as Mini version whereas the actual product is a Regular version
-
Class IIofficial
Hiossen Inc. recalls Osstem Implant System - Abutment ET Multi Abutment Size: 4.8D 3.0G/H- Abutment is intended for use with a dentPatient chart stickers provided inside the packaging may incorrectly identify ET Rigid Abutments as Regular version whereas the actual product is a Mini version; and identify the ET Multi Abutments as Mini version whereas the actual product is a Regular version
-
Class IIofficial
Hiossen Inc. recalls ET Rigid Abutment (Mini) Size: 4.5D 2.0G/H 4.0H- Intended for use with a dental implant to provide support forPatient chart stickers provided inside the packaging may incorrectly identify ET Rigid Abutments as Regular version whereas the actual product is a Mini version; and identify the ET Multi Abutments as Mini version whereas the actual product is a Regular version
-
Class IIofficial
Hiossen Inc. recalls Osstem Implant System - Abutment: ET Multi AbutmentSize: 4.8D 5.0GH - Abutment is intended for use with a dentPatient chart stickers provided inside the packaging may incorrectly identify ET Rigid Abutments as Regular version whereas the actual product is a Mini version; and identify the ET Multi Abutments as Mini version whereas the actual product is a Regular version
-
Class IIofficial
TAS Medical Inc recalls TISSUE APPROXIMATION SYSTEM (TAS)Tissue approximation straps (zip-ties) have broken before or during implantation so firm developed an interim zip-tie conditioning method submerging zip-ties in 104-degrees F sterile saline solution for 60 min prior to implantation to rehydrate the zip-tie straps. Broken zip-ties not observed during procedure could lead to future hernia recurrence, recurrent surgery to correct a large herniation.
-
Class IIofficial
Merit Medical Systems, Inc. recalls Prelude IDEAL 4 F Hydrophilic Sheath IntroducerHydrophilic Sheath Introducer labeled for 4F dilators may instead incorrectly contain 5F dilators. Incorrect dilator use may result in procedure delay.
-
Class IIofficial
Guangzhou Pluslife Biotech Co., Ltd. recalls Brand Name: MiniDock Product Name: Integrated Nucleic Acid Testing Device Model/Catalog Number: PM001 SoftwareDevices were distributed in the U.S. market without obtaining the required FDA premarket authorization (e.g., 510(k) clearance or PMA).
-
Class IIofficial
Guangzhou Pluslife Biotech Co., Ltd. recalls Brand Name: Pluslife SARS-CoV-2 Card Product Name: SARS-CoV-2 Nucleic Acid Testing Card Model/Catalog Number:Devices were distributed in the U.S. market without obtaining the required FDA premarket authorization (e.g., 510(k) clearance or PMA).
-
Class IIofficial
CareFusion 303, Inc. recalls BD Pyxis MedFlex 2.0 REF 1139-00 Bio-ID Spare Parts REF 353200-01 The BD Pyxis" MedFlex is an Automated DispenDue to fingerprint scanner failing resulting in the scanner heating up.
-
Class IIofficial
CareFusion 303, Inc. recalls BD Alaris Pump Module REF 8100 The BD Alaris System with Guardrails Suite MX is a modular infusion pump and moDue to User Manual/Direction for Use incorrectly instructing user to leave the safety clamp in the open position when reloading an infusion set. This issue potentially could result in an accidental over infusion if the roller clamp is left open.
-
Class IIofficial
Lumenis, Ltd. recalls (1) Lumenis Pulse 120H 30 ampThe initial current in certain chargers may lead to overheating and damage to the power resistors on the Alternating Current (AC) controller during the power-on sequence of the laser system, resulting in the laser system to not power on.
-
Class IIofficial
Physio-Control, Inc. recalls LIFEPAK 35 ECG cable REF 11111-000041Product shipped with incorrect IFU. IFU does not include proper cleaning/disinfection instructions
-
Class IIofficial
Physio-Control, Inc. recalls LIFEPAK 15 V4/Masimo Rainbow Sensors: Masimo¿ RD rainbow Adt 8¿ SpCODue to an error message that prevents users from utilizing carboxyhemoglobin saturation and methemoglobin saturation sensors on their monitor/defibrillator system.
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX - ANATOMIC LAT FIB PLATE 4H LT: Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX -ANATOMIC LAT FIB PLATE 4H RT: Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX -ANATOMIC LAT FIB PLATE 6H LT- Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 6H RT: Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 8H LT: Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 8H RT: Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- Product Name: ANATOMIC LAT FIB PLATE 10H LT Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 10H RT- Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX-P: ANATOMIC LAT FIB PLATE 12H LT- Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 12H RT- Anatomic Lateral Fibula PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX-MEDIAL TIBIA PLATE 6H LT-Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- MEDIAL TIBIA PLATE 6H RT-Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- MEDIAL TIBIA PLATE 10H LT- Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX-MEDIAL TIBIA PLATE 10H RT-Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX-MEDIAL TIBIA PLATE 12H LT-Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX--MEDIAL TIBIA PLATE 12H RT-Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- MEDIAL TIBIA PLATE 16H LT-Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Tyber Medical recalls A.L.P.S. mvX- MEDIAL TIBIA PLATE 16H RT -Medial Tibia PlateComplaints of the locking screw passing through the locking hole intra-operatively during use of the A.L.P.S. mvX Medial Tibia plates and Anatomic Lateral Fibula. r surgical delays have been reported with the use of the devices
-
Class IIofficial
Microbiologics Inc recalls Microbiologics Multi-Strain Human Papillomavirus (HPV) Control Panel (Inactivated Pellet)Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed and been discarded. The concentration of one target (HPV 16 L1) was low enough to cause QC failures, no detection, or invalid results on some instruments and assays.
-
Class IIofficial
Microbiologics Inc recalls Microbiologics Multi-Strain Human Papillomavirus (HPV) Verification Panel (Inactivated Pellet)Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed and been discarded. The concentration of one target (HPV 16 L1) was low enough to cause QC failures, no detection, or invalid results on some instruments and assays.
-
Class IIofficial
Kci USA, Inc. recalls 3M Prevena Plus 125 Therapy Unit and System Kits REF: PRE3021US Prevena Plus Duo Peel and Place 20cm System KiDue to increase in complaints related to leak alarms
-
Class IIofficial
Kci USA, Inc. recalls 3M V.A.C. VIA Negative Pressure Wound Therapy System REF: VIAKIT077D01/US - V.A.C. VIA 7 Day Kit VIAKIT07S05/ADue to increase in complaints related to leak alarms
-
Class IIofficial
Zhejiang Luyao Electronics Technology Co., Ltd. recalls Brand Name: HOMEDICS Product Name: Air Compression Leg Massager Model/Catalog Number: SR-160HJ Product DescripRegulatory documentation error and misleading color packaging claim.
-
Class IIofficial
Raysearch Laboratories Ab recalls Brand Name: RayStation Intended as a Radiation Therapy Treatment Planning System. Model/Catalog Number: 7.0.0.Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
Class IIofficial
Raysearch Laboratories Ab recalls Brand Name: RayStation -Intended as a Radiation Therapy Treatment Planning System Model/Catalog Number: 8.1.0.Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.