All recalls
Every recall from CPSC, FDA, USDA and NHTSA, newest first. Each one links to the agency's official notice. Looking for one product? Check a product.
9,374 recalls ยท page 107 of 188
-
Class IIofficial
Sklar Instruments recalls ECONO STERILE medical procedure kits labeled as: ECONO STERILE LEMPERT BONE RONG 6.25" STER25Reports of various packaging issues that may result in a breach of the sterile barrier.
-
Class IIofficial
Sklar Instruments recalls ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE PROBE W/EYE CS/50Reports of various packaging issues that may result in a breach of the sterile barrier.
-
Class IIofficial
Sklar Instruments recalls ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE OLSEN-HEG NH SMO DEL 5.5STER25Reports of various packaging issues that may result in a breach of the sterile barrier.
-
Class IIofficial
Medicrea International recalls UNiD" Adaptive Spine Intelligence UNiD Spine Analyzer Product Number SW3002 UDI-DI code 03613720286929 Two cloDue to software anomalies that may impact on rod planning specifically, certain optional surgical parameters may have had errors that resulted i incorrect calculations displayed on system. Impacted parameters includes the following: Roussouly Classification, Real Lumbar Lordosis and Real Thoracic Kyphosis, Barrey Ratio, and Lenke Classification.
-
Class IIofficial
Moximed, Inc. recalls MISHA Knee System Implant SmallKnee implant may fracture due to a supplier-related issue with one component that has nonconforming geometry at the distal end of the absorber component that may result in a reduced wall thickness and microcracks, which may lead to new or worsening symptoms of discomfort, swelling / edema, pain or stiffness, which may necessitate removal of the device.
-
Class IIofficial
Coloplast Manufacturing US, LLC recalls Folysil Silicone Foley CathetersA possible sterility issue was detected in Coloplast's facility on some Coloplast products.
-
Class IIofficial
Coloplast Manufacturing US, LLC recalls X-Flow prostatectomy catheterA possible sterility issue was detected in Coloplast's facility on some Coloplast products.
-
Class IIofficial
A L I Technologies Ltd recalls McKesson Cardiology Hemo softwareSoftware defect concerning autosave mechanism may result in the clinician administering incorrect medication(s).
-
Class IIofficial
A L I Technologies Ltd recalls Change Healthcare Cardiology Hemo softwareSoftware defect concerning autosave mechanism may result in the clinician administering incorrect medication(s).
-
Class IIofficial
A L I Technologies Ltd recalls Change Healthcare Cardiology Hemodynamics softwareSoftware defect concerning autosave mechanism may result in the clinician administering incorrect medication(s).
-
Class IIofficial
Accriva Diagnostics, Inc. recalls VerifyNow P2Y12 Platelet Reactivity TestPlatelet Reactivity Test distributed without appropriate US-FDA market clearance; if used healthcare personnel could use the baseline PRUTest measurement prior to initiating drug therapy, and then use the percent inhibition formula in the notice to manually calculate the percentage of platelet aggregation inhibition for a given patient receiving drug treatment with P2Y12 receptor inhibitor.
-
Class IIofficial
Microvention Inc. recalls MicroventionSterility assurance; microcatheter inner packaging may contain incomplete seal.
-
Class IIofficial
ConvaTec, Inc recalls Esteem Synergy Stomahesive Skin BarrierOstomy skin barrier package contains a pre-cut wafer of 28mm instead of 16mm and/or 35mm pre-cut wafers, as stated package labeling. If pre-cut wafers are too big the device cannot be used and if the pre-cut wafer is too small and the device user tries to apply, this could cause abrasion, stomal cut, and bleeding
-
Class Iofficial
Trokamed GmbH recalls SheathIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
-
Class Iofficial
Trokamed GmbH recalls SheathIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
-
Class Iofficial
Trokamed GmbH recalls SheathIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
-
Class Iofficial
Trokamed GmbH recalls SheathIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
-
Class IIofficial
3B Medical, Inc. recalls Brand Name: 3B MedicalThe devices were inadvertently shipped after their expiration date.
-
Class IIofficial
IsoTis OrthoBiologics, Inc. recalls OsteoCove PuttyHydration issue resulting in the product being less cohesive and moldable than intended due to an issue with the polymer.
-
Class IIofficial
IsoTis OrthoBiologics, Inc. recalls OsteoSurge 100 Demineralized Bone Matrix Putty with Accell Bone MatrixIncorrect expiration date listed on the outer box, which does not align with the correct expiration date listed on the inner tray.
-
Class IIofficial
3M Unitek Corporation recalls 3M Unitek Transbond Plus Self-Etching Primer REF 712-090 (100 unit box) 712-091 (20 unit box) Transbond Plus SDue to an increase of complaints for bracket bond failures and skin irritation or blistering.
-
Class IIofficial
Beckman Coulter, Inc. recalls Access Intact PTH assayBeckman Coulter has identified that some Access PTH reagent packs from lot 339071 may be over- or under-filled in well 0. The dispensed material in well 0 could be above or below specification, risking sealing issues, contamination, instrument errors, delays, or inaccurate results with a negative bias and increase in imprecision. The issue was confirmed on 10 April 2024 by Beckman Coulter through an internal non-conformance (NC-INT-66585). The well 0 scale on the filling line began malfunctioning on the fill immediately before PTH. The malfunction was not noticed until the majority of PTH was filled.
-
Class IIofficial
Applied Medical Technology Inc recalls AMT Mini Enteral Extension SetThe extension sets subject to this recall have ENFit connections, although they should have non- ENFit connections. ENFit connectors will only fit with other ENFit-compatible devices, and will not fit with non-ENFit connectors.
-
Class IIofficial
O&m Halyard, Inc. recalls Brand Name: HALYARD Product Name: Laparotomy Pack Model/Catalog Number: 88231 Software Version: N/A Product DeElevated residues of anti-block/slip additive used in manufacturing found within sterile packaging.
-
Class IIofficial
Spectranetics Corporation recalls Turbo Elite Laser Atherectomy Catheter Model Number / UDI-DI code / Product Description 414-151 / 989930000531Due to complaints received for the marker band detaching from the distal tip of the catheter and remaining in the patient as laser catheter was retracted.
-
Class IIofficial
Spacelabs Healthcare, Ltd. recalls Eclipse PRO REF 98700 The Spacelabs model 98700 is a portable non-invasive Holter recorder intended to recordDue to a manufacturing error the incorrect device serial number was potentially programmed into the holter recorder. The physical serial number label on the device might not match the serial number programmed into the device.
-
Class IIofficial
Spacelabs Healthcare, Ltd. recalls Eclipse Mini REF 98900 The Eclipse MINI Model 98900 is a portable non-invasive continuous ambulatory ECG patchDue to a manufacturing error the incorrect device serial number was potentially programmed into the holter recorder. The physical serial number label on the device might not match the serial number programmed into the device.
-
Class IIofficial
Angiodynamics, Inc. recalls AURYON LASER SYSTEM 100-120 VAC. Model Number: EXM001. Product Number: EXM-2001-1100Potential for procedural delays or interruptions during use of the Auryon Atherectomy System due to the Auryon Atherectomy System not advancing to the Activation (Ready) mode.
-
Class IIofficial
Spacelabs Healthcare, Inc. recalls Xhibit Telemetry ReceiverTelemetry receiver systems may experience a Windows proxy Issue causing the system to shut down and restart (Offline displayed), lasting approximately 1 to 1.5 minutes, which will cause temporary loss of monitoring. If a clinical event occurred during this period, staff may not detect until the system restarts; necessary clinical intervention could be delayed.
-
Class IIofficial
Spacelabs Healthcare, Inc. recalls Xhibit Telemetry Receiver with SoftwareTelemetry receivers with affected software versions may experience unsolicited system shut down and restart (Offline displayed), lasting approximately 1 to 1.5 minutes, which will cause temporary loss of monitoring. If a clinical event occurred during this period, staff may not detect until the system restarts and necessary clinical intervention could be delayed.
-
Class IIofficial
GE Medical Systems, LLC recalls GE Healthcare Optima XR200amxGE HealthCare has become aware that in certain Optima XR200/220/240amx systems that have had a column replacement performed, some bolts used in the Column Safety mechanism can be missing. If these bolts are missing and a failure of the internal counterpoise cable occurs, the Column Safety mechanism will not work properly causing the arm with X-ray tube and collimator to drop downward on the column track.
-
Class IIofficial
GE Medical Systems, LLC recalls GE Healthcare Optima XR220amxGE HealthCare has become aware that in certain Optima XR200/220/240amx systems that have had a column replacement performed, some bolts used in the Column Safety mechanism can be missing. If these bolts are missing and a failure of the internal counterpoise cable occurs, the Column Safety mechanism will not work properly causing the arm with X-ray tube and collimator to drop downward on the column track.
-
Class IIofficial
GE Medical Systems, LLC recalls GE Healthcare Optima XR240amxGE HealthCare has become aware that in certain Optima XR200/220/240amx systems that have had a column replacement performed, some bolts used in the Column Safety mechanism can be missing. If these bolts are missing and a failure of the internal counterpoise cable occurs, the Column Safety mechanism will not work properly causing the arm with X-ray tube and collimator to drop downward on the column track.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: Thunderbeat Front-ActThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: THUNDERBEAT 5 mmThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Olympus Corporation of the Americas recalls Brand Name: Olympus Thunderbeat Front-Actuated Grip Type S Hand Instrument Product Name: ThunderbeatThe probe tips of the hand instruments are being damaged or breaking including pad damage and detachment.
-
Class IIofficial
Adept Medical Ltd recalls Otological Ventilation Tube - T-Tube 6mm - Silicone; Product Code: NZ3306/NZ3306-2;Lack of 510(k) clearance.
-
Class IIofficial
Adept Medical Ltd recalls Otological Ventilation Tube - T-Tube 6mm - Double - Silicone; Product Code: NZ3306-2;Lack of 510(k) clearance.
-
Class IIofficial
Adept Medical Ltd recalls Otological Ventilation Tube - T-Tube 9mm - Double - Silicone; Product Code: NZ3309-2;Lack of 510(k) clearance.
-
Class IIofficial
Adept Medical Ltd recalls Otological Ventilation Tube - T-Tube 9mm - Silicone; Product Code: NZ3309;Lack of 510(k) clearance.
-
Class IIofficial
Adept Medical Ltd recalls Otological Ventilation Tube - T-Tube 12mm - Silicone; Product Code: NZ3312;Lack of 510(k) clearance.
-
Class IIofficial
Adept Medical Ltd recalls Otological Ventilation Tube - T-Tube 12mm - Double - Silicone; Product Code: NZ3312-2;Lack of 510(k) clearance.