All recalls
Every recall from CPSC, FDA, USDA and NHTSA, newest first. Each one links to the agency's official notice. Looking for one product? Check a product.
9,374 recalls · page 138 of 188
-
Class Iofficial
Smiths Medical ASD Inc. recalls smiths medical portex BLUselectThere is the potential for a disconnection of the pilot balloon from the tracheostomy inflation line within specific lots of the BLUSelect, BLUgriggs and BLUperc products due to a manufacturing defect.
-
Class Iofficial
Smiths Medical ASD Inc. recalls smiths medical portex BLUgriggs Percutaneous Dilation Procedural Trays with BLUselect tracheotomy tubesThere is the potential for a disconnection of the pilot balloon from the tracheostomy inflation line within specific lots of the BLUSelect, BLUgriggs and BLUperc products due to a manufacturing defect.
-
Class Iofficial
Smiths Medical ASD Inc. recalls smiths medical portex BLUperc Percutaneous Diliation Procedural Trays with BLUselect tracheostomy tubesThere is the potential for a disconnection of the pilot balloon from the tracheostomy inflation line within specific lots of the BLUSelect, BLUgriggs and BLUperc products due to a manufacturing defect.
-
Class Iofficial
Philips North America Llc recalls SENSE XL TORSO COIL 1.5T. 16-element receive only coil for torso and abdomen imaging in Philips MR Intera andPotential for coils to heat up and harm patients (burn).
-
Class Iofficial
Philips North America Llc recalls SENSE XL TORSO COIL 3.0T. 16-element receive only coil for torso and abdomen imaging in Philips MR Intera andPotential for coils to heat up and harm patients (burn).
-
Class Iofficial
Philips North America Llc recalls SENSE XL TORSO COIL 1.5T Mk2. 16-element receive only coil for torso and abdomen imaging in Philips MR InteraPotential for coils to heat up and harm patients (burn).
-
Class IIofficial
MICROspecialties, Inc. recalls Synergetics I Pack Injection Kit- Tray for use with Ophthalmic injections Model/Catalog Number: 18060Could not confirm products were exposed to the proper sterilization cycle can potentially cause post operative wound infection or injection site infection.
-
Class IIofficial
MICROspecialties, Inc. recalls Synergetics I-Pack Injection Kit with Drape -For use with Ophthalmic injections Model/Catalog Number: 18061Could not confirm products were exposed to the proper sterilization cycle can potentially cause post operative wound infection or injection site infection.
-
Class IIofficial
MICROspecialties, Inc. recalls Synergetics I Pack Injection Kit Custom-Tray for use with Ophthalmic injections Model/Catalog Number: 18069 PrCould not confirm products were exposed to the proper sterilization cycle can potentially cause post operative wound infection or injection site infection.
-
Class IIofficial
MICROspecialties, Inc. recalls Synergetics I Pack Injection Kit with Wire Speculum- Tray for use in Opthalmic Injection Model/Catalog Number:Could not confirm products were exposed to the proper sterilization cycle can potentially cause post operative wound infection or injection site infection.
-
Class IIofficial
Beckman Coulter Mishima K.K. recalls DxC 500 AU Clinical Chemistry AnalyzerThere are two software bug issues with the analyzer. Issue 1: When a dedicated rack is reserved for calibration, after a calibration test has been placed and completed, the same rack may be used to place both a patient order and a calibration order. When a patient sample and a non-barcoded calibrator tube is processed on the rack, the calibration result will be reported as a patient result. Issue 2: calibration with expired calibrator. They both may cause erroneous patient results, but the probability of serious adverse health consequences or death is unlikely.
-
Class IIofficial
Zyno Medical LLC recalls Zyno Medical Z800Zyno Medical has found that certain Z800, Z800F, Z800W, and Z800WF pumps have faulty power supply modules that will not provide a charge to the rechargeable battery within the pump. This may lead to the battery having insufficient or no charge available to the pump when it is unplugged from the AC mains power.
-
Class IIofficial
Baxter Healthcare Corporation recalls VidiaPort carrying armBaxter Healthcare Corporation is issuing an Urgent Medical Device Correction due to customer reports of thermal skin injuries when using the iLED 7 surgical light system products listed below. Specific VidiaPort and Trulight product codes are also impacted as they are equipped with iLED 7 light-heads
-
Class IIofficial
Baxter Healthcare Corporation recalls Trulight 5000/3000 Surgical LightBaxter Healthcare Corporation is issuing an Urgent Medical Device Correction due to customer reports of thermal skin injuries when using the iLED 7 surgical light system products listed below. Specific VidiaPort and Trulight product codes are also impacted as they are equipped with iLED 7 light-heads
-
Class IIofficial
Baxter Healthcare Corporation recalls iLED 7 surgical lightsBaxter Healthcare Corporation is issuing an Urgent Medical Device Correction due to customer reports of thermal skin injuries when using the iLED 7 surgical light system products listed below. Specific VidiaPort and Trulight product codes are also impacted as they are equipped with iLED 7 light-heads
-
Class IIofficial
Seaspine Orthopedics Corporation recalls Brand Name: Meridian Angled Awl Fixed Product Name: Angled Awl Fixed Model/Catalog Number: RA2-003015 ProductInsufficient weld around the cap component of the instrument is insufficient to withstand impaction forces.
-
Class IIofficial
Beckman Coulter, Inc. recalls Dxl 9000 Access Immunoassay AnalyzerThe analyzers were built with nonconforming USB cables made with brass contacts instead of specified gold contacts. Brass contacts may corrode over time, leading to loss of internal instrument communication and delayed patient results.
-
Class IIofficial
Aspen Surgical recalls Endoscopic Kittner Blunt Dissecting InstrumentThe affected products may have been packaged with a defect in the sterile barrier seal. As a result, the integrity of the sterile barrier may be compromised.
-
Class IIofficial
Nalu Medical, Inc. recalls Neurostimulation Kit (PortedNeurostimulation Systems have a manufacturing non-conformance that may reduce the efficiency of the radiofrequency signals between the Implantable Pulse Generator (IPG) and the Therapy Disc, causing the IPG to be non-functional, which causes the device to be non-functional so it will no longer inhibit the transmission of pain signals to the brain.
-
Class IIofficial
Stryker Corporation recalls The Non-Sterile Flyte hood covers the user s head and neck region and is intended to be worn with commerciallyExpired Products distributed to customers
-
Class IIofficial
Stryker Corporation recalls CurvedExpired Products distributed to customers
-
Class IIofficial
Stryker Corporation recalls This product is a single use sterile device that is used to direct the lesion to the targeted site. Each cannuExpired Products distributed to customers
-
Class IIofficial
Baxter Healthcare Corporation recalls Welch Allyn CP150 Electrocardiograph with Spirometry OptionDuring manufacturing, the step to install an Electromagnetic Interference (EMI) Absorber was omitted. The purpose of the EMI absorber is to prevent EMI leakage that might potentially affect other devices in the vicinity or the device itself may be vulnerable to EMI resulting in device malfunction or unavailability.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls 190904 2008K@HOME HEMODIALYSIS SYSTEM W/ BIBAG - Blood Pump Rotor spare partAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls 190828: 2008K@HOME HEMODIALYSIS SYSTEM - Blood Pump Rotor spare partAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls 191014: 2008K@HOME HD SYSTEM W/BIBAG (CANADA) - Blood Pump Rotor spare partAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls 190395: 2008K@HOME MACHINEAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls RTL190395: 2008K@HOME MACHINEAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls RTL190828: 2008K@HOME HEMODIALYSIS SYSTEM - Blood Pump Rotor spare partAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls RTL190904: 2008K@HOME HEMODIALYSIS SYSTEM W/ BIBAG - Blood Pump Rotor spare partAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Fresenius Medical Care Holdings, Inc. recalls RTLR190395: 2008K@HOME MACHINEAn increased number of complaints were reported on the Blood Pump Rotor (P/N - F40015481 REV A) after a period of use by clinics noting loose/dislodged guide sheaves.
-
Class IIofficial
Qiagen Sciences LLC recalls QIAcube Connect MDx - IVD Instrument designed to perform automated isolation and purification of nucleic acidsHeater shaker module does not perform heating if the temperature is set below 40¿C for static incubation steps when running IVD protocol QIAamp¿ DSP DNA Mini Kit (cat. no. 61304), Protocol: Isolation of genomic DNA from Gram-positive bacteria (Script filename: Kt_name_Bacteria (Gram+) or rY'east_Enzymatic Lysis_ V2) which could potentially cause delayed or erroneous results depending on the downstream assay.
-
Class IIofficial
Microtek Medical Inc. recalls C-Flow Bag DecanterDuring sterile barrier testing performed on the decanter product line, the samples were identified to have pin holes and tears in the packaging film.
-
Class IIofficial
Microtek Medical Inc. recalls Bag Decanter IIDuring sterile barrier testing performed on the decanter product line, the samples were identified to have pin holes and tears in the packaging film.
-
Class IIofficial
Microtek Medical Inc. recalls Bottle DecanterDuring sterile barrier testing performed on the decanter product line, the samples were identified to have pin holes and tears in the packaging film.
-
Class IIofficial
Microtek Medical Inc. recalls Vial DecanterDuring sterile barrier testing performed on the decanter product line, the samples were identified to have pin holes and tears in the packaging film.
-
Class IIofficial
Microtek Medical Inc. recalls Transfer DeviceDuring sterile barrier testing performed on the decanter product line, the samples were identified to have pin holes and tears in the packaging film.
-
Class IIofficial
Treace Medical Concepts, Inc. recalls Nanoplasty 3D Bunion Correction System ImplantPotential issue causing a higher frequency of interference with locking screws and/or inserter rods than anticipated, resulting in screws stripping and/or not fully seating in the plates and/or interface issues between inserter rods and plates.
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls AXIOM MULTIX MT - Intended Radiographic X ray Table is a patient table used in conjunction with the Siemens MuShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls AXIOM MULTIX MT - Intended Radiographic X ray Table is a patient table used in conjunction with the Siemens MuShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls AXIOM MULTIX MP - Intended Radiographic X ray Table is a patient table used in conjunction with the Siemens MuShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls AXIOM MULTIX MP - Inended Radiographic X ray Table is a patient table used in conjunction with the Siemens MulShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls AXIOM Vertix MD - The Vertix MD Trauma has been specially designed for examining emergency and accident patienShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls AXIOM Vertix Solitaire - The Vertix MD Trauma has been specially designed for examining emergency and accidentShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls MULTIX TOP - Intended Use: The Multix TOP I PRO Radiographic X ray Table is a patient table used in conjunctioShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls MULTIX TOP - Intended Use: The Multix TOP I PRO Radiographic X ray Table is a patient table used in conjunctioShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls ZE for Vertix Solitaire - The AXIOM Vertix Solitaire is a component and has been specially designed for examinShort circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
-
Class Iofficial
Abiomed, Inc. recalls Impella CP with SmartAssistNine (9) Impella CP pumps failed inspection and were inadvertently released.
-
Class IIofficial
Zoll Medical Corporation recalls ZOLL Powerheart G5 AEDG5 Semi-Automatic AED is shipped, with a protective film over its front panel, to protect the screen and shock button from cosmetic damage during shipping. It has come to our attention that customers may not be removing the protective film during deployment of the product. If the protective film is left adhered to the front bezel it may prevent the user from actuating the shock button and may lead to a delay or prevent delivery of defibrillation therapy to a victim suffering from sudden cardiac arrest
-
Class IIofficial
Maquet Cardiovascular, LLC recalls The VASOVIEW HEMOPRO Endoscopic Vessel Harvesting Systems is designed for use in conjunction with the 7 mm ExtThere were 27 complaints between March 22, 2024, and April 30, 2024, related to VH-3500 and VH-4000, reporting that the C-Ring wire was straightened (due to insufficient bend radius) and that the distance between C-Ring and Harvesting Tool was closer than normal. No adverse events have been reported to date in direct association with this issue.