Class IIIofficial
VistaPharm LLC recalls Aminocaproic Acid Oral SolutionFailed Excipient Specifications: high content of ethylene glycol (EG)
-
Class Iofficial
Safeway Fresh Foods LLC recalls HEB Kale GreensPossible Listeria monocytogenes contamination
-
Class Iofficial
Safeway Fresh Foods LLC recalls HEB Kale GreensPossible Listeria monocytogenes contamination
-
Class Iofficial
Safeway Fresh Foods LLC recalls Little Bear Fresh KalePossible Listeria monocytogenes contamination
-
Class IIofficial
BioFire Diagnostics, LLC recalls FilmArray TORCH REF HTFA-ASY-0104. HTFA-ASY-0104 is the BIOFIRE TORCH Base which includes barcode scannerDue to an increased risk of degradation of the power entry switch resulting from arcing inside of the power switch that may result in carbon build-up on the switch contacts. The carbon build-up may lead to excess heating inside of the power switch, subsequently leading to deformation of the power switch case. The deformation can create an opportunity for a power switch electrical short. In addition to an electrical short, deformation may result in an open circuit causing the power switch to fail. This event would only occur after the product is in use.
-
Class IIofficial
EMD Millipore Corporation recalls Lugol s Iodine Solution 500MLDue to the incorrect packaging utilized with lot 3124, there' s an improper seal between the cap and bottle. With an improper seal the Assay (current specification of 24.8 to 27.2 mL) is expected to continue to drop over time as iodine vapors continue to dissipate from the bottles.
-
Class IIofficial
BioFire Diagnostics, LLC recalls BIOFIRE Blood Culture Identification 2 (BCID2) PanelRoutine quality control testing of affected blood culture identification panel with affected control panel may need to be amended, due to control panel/instrument characteristic changes, that lead C. tropicalis to be amplified in some portion of test runs, but then it's reported as "Not Detected" because the assay amplicon Tm is outside the acceptable limit assigned for calling positive results.
-
Class IIofficial
Bebig Isotopentechnik Gmbh recalls SagiPlan 2.2Due to software malfunction, numerical values may be rounded resulting in inaccurate measurements.
-
Class IIofficial
Siemens Medical Solutions USA, Inc recalls ARTIS icono (ceiling configuration)Potential hardware issue for ARTIS icono ceiling system: collision sensor may falsely signal non-existing collisions for up to half an hour when the system is switched off for a longer time (e.g., overnight) and switched on. During this time, system movement is only possible with the "override" function with very slow speed and without further collision protection. This may lead to temporary unavailability of the system for diagnostic and therapeutic usage.
-
Class Iofficial
Noah's Wholesale LLC recalls THE ROCKMarketed Without an Approved NDA/ANDA: FDA analysis found the product to be tainted with Sildenafil an ingredient found in an FDA approved product for the treatment of male sexual enhancement, making this an unapproved drug.
-
Class IIofficial
La Michoacana 100% Natural Inc recalls ICE CREAM BARUndeclared Yellow #5, Yellow #6, and Red #40
-
Class IIofficial
Aizu Olympus Co., Ltd. recalls CF-HQ190L EVIS EXERA III COLONOVIDEOSCOPESpecific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in loss of image, decreased suction, or impact the ability to effectively reprocess the device. This in turn may lead to unanticipated delay to treatment, or patient exposure to contaminated material and subsequent infection.
-
Class IIofficial
Aizu Olympus Co., Ltd. recalls GIF-H190Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in loss of image, decreased suction, or impact the ability to effectively reprocess the device. This in turn may lead to unanticipated delay to treatment, or patient exposure to contaminated material and subsequent infection.
-
Class IIofficial
Aizu Olympus Co., Ltd. recalls GIF-HQ190Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in loss of image, decreased suction, or impact the ability to effectively reprocess the device. This in turn may lead to unanticipated delay to treatment, or patient exposure to contaminated material and subsequent infection.
-
Class IIofficial
Aizu Olympus Co., Ltd. recalls PCF-H190DLSpecific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in loss of image, decreased suction, or impact the ability to effectively reprocess the device. This in turn may lead to unanticipated delay to treatment, or patient exposure to contaminated material and subsequent infection.
-
Class IIofficial
Aizu Olympus Co., Ltd. recalls PCF-H190LSpecific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in loss of image, decreased suction, or impact the ability to effectively reprocess the device. This in turn may lead to unanticipated delay to treatment, or patient exposure to contaminated material and subsequent infection.
-
Class Iofficial
MEDLINE INDUSTRIES, LP - Northfield recalls Tracheostomy care kits: (1) Medline Tracheostomy Clean and Care Tray with 14 Fr Suction CatheterThe component tracheostomy brush has a sharp edge at the tip that can potentially puncture tubing during use and/or cause user injury. Additionally, there have been incidents of the tracheostomy brush bristles detaching prior to use in the packaging and/or during use.
-
Class Iofficial
MEDLINE INDUSTRIES, LP - Northfield recalls (1) Nursing Skills kitThe component tracheostomy brush has a sharp edge at the tip that can potentially puncture tubing during use and/or cause user injury. Additionally, there have been incidents of the tracheostomy brush bristles detaching prior to use in the packaging and/or during use.
-
Class Iofficial
MEDLINE INDUSTRIES, LP - Northfield recalls (1) Nurse KitThe component tracheostomy brush has a sharp edge at the tip that can potentially puncture tubing during use and/or cause user injury. Additionally, there have been incidents of the tracheostomy brush bristles detaching prior to use in the packaging and/or during use.
-
Class IIofficial
Zimmer Biomet Spine Inc. recalls Vitality Polyaxial ScrewSpinal fixation system 7.5mmx 50mm screws are packaged with the correct labeling, but the screws themselves were laser marked with an incorrect size description of 7.5 x 40; use of incorrect screws could lead to screw perforation and indention of vascular or other structures.
-
Class IIofficial
Dr. Reddy's Laboratories, Inc. recalls Montelukast Sodium TabletsPresence of Foreign Tablet(s)/Capsule(s): A foreign tablet was found in a bottle of Montelukast Sodium Tablets, USP 10mg, identified as metoprolol 25 mg.
-
Class IIofficial
Lgnds LLC recalls TYSON 2.0Finished product contains kratom (an unapproved food additive) and pH is over 5.0. The process authority letter classified product as acidified and pH cannot exceed 3.30.
-
Class IIofficial
Lgnds LLC recalls TYSON 2.0Finished product contains kratom (an unapproved food additive) and pH is over 5.0. The process authority letter classified product as acidified and pH cannot exceed 3.30.
-
Class Iofficial
Baxter Healthcare Corporation recalls Novum IQ Syringe infusion systemBaxter is issuing an Urgent Medical Device Correction for the Novum IQ Syringe Pump. Baxter identified that after multiple downstream occlusion alarms, the pump may display an Infusion Complete alarm even though uninfused fluid remains in the syringe.
-
Class IIofficial
Avanos Medical, Inc. recalls AVANOS BALLARD Closed Suction System for AdultsCertain lots of BALLARD Closed Suction System for Adults, 14 Fr, DSE, MDI were labeled as not being made with Di(2-ethylhexyl) phthalate (DEHP); however, Avanos has determined that the tubing components of the product did contain DEHP.
-
Class IIofficial
Breas Medical, Inc. recalls with Notch 22M/15F sold as part of Breas Medical MPV circuit 2 pc Kits: 006093Produced with unintended open slits on the side of the mouthpiece body, may result in insufficient ventilation in spontaneous breathing patients using MPV-VCV and MPV-PCV modes of ventilation
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls TILAPIA FILLET 5-7 OZ BLSLA frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls SHRIMP RAW P&D WHITE 16-20 CTA frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls MILK HOMO GALLONA frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls CHEESE VELVEETA LOAF; CHEESE CHEDDAR SLICE MILD; CHEESE STICK MOZZ BATTERED; CHEESE CHEDDAR SLICE MILDA frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls LEMON CHOICE MINI PK 34-44 CT; STRAWBERRY SLICED 4-1A frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls TATER KEG BACON CHEDDAR CHIVE; OKRA CUT HEAVILY BREADED IQF; POTATO TATER TOTS; FRENCH FRIES SC 3/8 IN; JALAPEA frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls BREAD SANDWICH WHITE LOAFA frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class IIofficial
Ben E Keith Foods - Fort Worth recalls DRESSING GREEK FETAA frozen/ refrigerated food trailer holding various types and brands of frozen/ refrigerated foods were temperature abused.
-
Class Iofficial
Olympus Corporation of the Americas recalls BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Numbers BF-1T150There is a risk of endobronchial combustion if high-frequency cauterization is performed while supplying oxygen [and/or] the electrode section of the electrosurgical accessory is too close to the distal end of the endoscope.
-
Class Iofficial
Olympus Corporation of the Americas recalls EVIS EXERA II BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Number Q180-ACThere is a risk of endobronchial combustion if high-frequency cauterization is performed while supplying oxygen [and/or] the electrode section of the electrosurgical accessory is too close to the distal end of the endoscope.
-
Class Iofficial
Olympus Corporation of the Americas recalls EVIS EXERA II BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Numbers BF-1T180There is a risk of endobronchial combustion if high-frequency cauterization is performed while supplying oxygen [and/or] the electrode section of the electrosurgical accessory is too close to the distal end of the endoscope.
-
Class Iofficial
Olympus Corporation of the Americas recalls EVIS EXERA III BRONCHOVIDEOSCOPE Model Numbers BF-1TH190There is a risk of endobronchial combustion if high-frequency cauterization is performed while supplying oxygen [and/or] the electrode section of the electrosurgical accessory is too close to the distal end of the endoscope.
-
Class Iofficial
Olympus Corporation of the Americas recalls EVIS EXERA b BRONCHOVIDEOSCOPE OLYMPUS Model Number BF-XT190There is a risk of endobronchial combustion if high-frequency cauterization is performed while supplying oxygen [and/or] the electrode section of the electrosurgical accessory is too close to the distal end of the endoscope.
-
Class Iofficial
Olympus Corporation of the Americas recalls EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS Model Number BF-P190There is a risk of endobronchial combustion if high-frequency cauterization is performed while supplying oxygen [and/or] the electrode section of the electrosurgical accessory is too close to the distal end of the endoscope.
-
Class IIofficial
Change Healthcare Canada Company recalls Change Healthcare Radiology SolutionsChange Healthcare has identified a software issue where Change Healthcare Radiology Solutions 14.0, 14.1, and 14.2 may not update records in external applications.
-
Class IIofficial
Maquet Medical Systems USA recalls Cardiohelp-iIt was found that the fixation (weld) employed by the supplier of the nut bolt to the slide rail plate was insufficient. The deficient weld allows the nut bolt to break off from the slide rail plate with slight manual force.
-
Class IIofficial
Medtronic Inc recalls Medtronic Mo.Ma Ultra Proximal Cerebral Protection DeviceThe Mo.Ma Ultra device manifold is labelled with 2 stickers, an inferior and superior sticker, one on each side of the manifold. These stickers label the common carotid artery (CCA) proximal balloon and external carotid artery (ECA) distal balloon inflation and deflation ports. Both sides of the complaint units manifold were labelled with the superior label leading to an incorrect identification of the proximal and distal inflation /deflation ports when viewing the devices from the inferior side.
-
Class IIofficial
Medtronic Inc recalls Medtronic Mo.Ma Ultra Proximal Cerebral Protection DeviceThe Mo.Ma Ultra device manifold is labelled with 2 stickers, an inferior and superior sticker, one on each side of the manifold. These stickers label the common carotid artery (CCA) proximal balloon and external carotid artery (ECA) distal balloon inflation and deflation ports. Both sides of the complaint units manifold were labelled with the superior label leading to an incorrect identification of the proximal and distal inflation /deflation ports when viewing the devices from the inferior side.
-
Class IIofficial
Medtronic Inc recalls Medtronic Mo.Ma Ultra Proximal Cerebral Protection DeviceThe Mo.Ma Ultra device manifold is labelled with 2 stickers, an inferior and superior sticker, one on each side of the manifold. These stickers label the common carotid artery (CCA) proximal balloon and external carotid artery (ECA) distal balloon inflation and deflation ports. Both sides of the complaint units manifold were labelled with the superior label leading to an incorrect identification of the proximal and distal inflation /deflation ports when viewing the devices from the inferior side.
-
Class Iofficial
Unomedical A/S recalls VariSoft infusion setThe Varisoft infusion set is used in conjunction with tandem insulin pumps. The defect reported was damage to the connector piece during manufacturing. This damage results in the connector becoming detached more easily from the insulin set than expected, requiring less force to disconnect than intended. Disconnection, when not detected, for example during sleep, leads to missed basal dosing. which in turn can result in elevated blood glucose and ketone level (nocturnal hyperglycemia). Diabetic ketoacidosis.
-
Class Iofficial
Unomedical A/S recalls VariSoft infusion setThe Varisoft infusion set is used in conjunction with tandem insulin pumps. The defect reported was damage to the connector piece during manufacturing. This damage results in the connector becoming detached more easily from the insulin set than expected, requiring less force to disconnect than intended. Disconnection, when not detected, for example during sleep, leads to missed basal dosing. which in turn can result in elevated blood glucose and ketone level (nocturnal hyperglycemia). Diabetic ketoacidosis.hyperglycemia). Diabetic ketoacidosis.
-
Class Iofficial
Unomedical A/S recalls VariSoft infusion setThe Varisoft infusion set is used in conjunction with tandem insulin pumps. The defect reported was damage to the connector piece during manufacturing. This damage results in the connector becoming detached more easily from the insulin set than expected, requiring less force to disconnect than intended. Disconnection, when not detected, for example during sleep, leads to missed basal dosing. which in turn can result in elevated blood glucose and ketone level (nocturnal hyperglycemia). Diabetic ketoacidosis.
-
Class IIofficial
Becton Dickinson & Company recalls BD Alaris Pump infusion sets (Product NameAffected infusion sets labeled as free of DEHP actually do contain di(2-ethylhexyl) phthalate (DEHP).
-
Class IIofficial
Becton Dickinson & Company recalls BD gravity sets (Product NameAffected infusion sets labeled as free of DEHP actually do contain di(2-ethylhexyl) phthalate (DEHP).